The CRM IV leds are configured from the [[Event Handler]] in [[AlphaPro]]. Go to '''Users & Stations''', select the CRM IV in the list box, and press '''Events'''.
+
The CRM IV leds are configured from the [[Event Handler]] in [[AlphaPro]]. Go to '''Users & Stations''', select the CRM IV in the list box, and press '''Events'''. '''Insert''' a new event with the following parameters:
Insert a new event with the following parameters:
 
  
 
=== Buzzer ===
 
=== Buzzer ===

Revision as of 23:45, 9 November 2007

Control Room Master IV.jpg

Features

  • Compact flush mount station with single-touch keys and 4x20 character display with backlight.
  • 1 Handset and 2 additional single-touch key modules (each with 48 keys) can be attached.
  • Call-in annunciation with full display information.
  • Queuing of calls according to priority and time of arrival, 256 priority levels.
  • Parallel servers and transfer of command support.
  • Display information on station name/number or Call Request description.
  • Auto acknowledgment to call-in point by flashing station lamp, voice message and ringing.
  • Single-touch access to stations, group calls, audio monitoring, public address zones, radio channels and telephone lines. Single-touch keys has 1 green and 1 red indicator LED each. Keys has PTT function and programmable cancel function on key release.
  • Programmable LED and buzzer functions.
  • Technical alarms with 60 different display texts and 256 priority levels.
  • Noise canceling goose-neck microphone with automatic sensitivity adjustment.
  • Requires AMC software 07.20 or newer in the exchange. Programming: AlphaPro 07.20 or newer.
  • Line monitoring of all extension lines.

Description

This advanced control room master features a large 4 x 20 character alphanumeric display with backlight, full dialing keypad, 4 programmable single-touch keys with indicators, (e.g. used as answer-next-in-queue key), sensitive gooseneck-microphone and a powerful 1W loudspeaker. The station offers full loudspeaking conversation with automatic switching of the speech direction. Manual override of speech direction is also possible. The station’s 4 line display gives full information on the current conversation and calls waiting in queue. The information includes directory number, name/location and priority level. Convenient answer-next-in-queue button allows you to respond to calls according to priority and time of arrival. The station has aluminum front panels. 2-pair mm2 (24 AWG) twisted telephone cable is required between the station and the exchange. The maximum distance is 1.4 km (4600 feet) with 0.5 mmø cable. Greater distances (up to 2 km) are possible using heavier wires. The station is equipped with screw terminals, external cable is not included. The station requires a local +12V DC power supply.

Installation

Control Room Master IV Installation.jpg


Configuration

DAK leds

The CRM IV leds are configured from the Event Handler in AlphaPro. Go to Users & Stations, select the CRM IV in the list box, and press Events. Insert a new event with the following parameters:

Buzzer

Backlight