Difference between revisions of "Audio Program (ICX-AlphaCom)"
From Zenitel Wiki
Line 1: | Line 1: | ||
The AlphaCom system is prepared for distribution of '''audio programs'''. There must be an external audio source as input to each program, a radio, CD-player, alarm device or other sound input. | The AlphaCom system is prepared for distribution of '''audio programs'''. There must be an external audio source as input to each program, a radio, CD-player, alarm device or other sound input. | ||
− | A number of inputs for audio programs are available, depending on the system configuration. By default 6 audio program inputs are available via the [[APC]] board for the [[AlphaCom E20]] and [[AlphaCom E26]], and 2 audio program inputs for the [[AlphaCom E7]]. | + | A number of inputs for audio programs are available, depending on the system configuration. By default 6 audio program inputs are available via the [[APC]] board for the [[AlphaCom E20]] and [[AlphaCom E26]], and 2 audio program inputs for the [[AlphaCom E7]]. The number of audio program inputs can be expanded by using [[AGA#Multi_Program_Distribution|AGA board]]. |
== Audio Program selection == | == Audio Program selection == | ||
To select a program, dial the program number (default 801 - 806, 8101 - 8132). The program is temporarily disconnected by outgoing and incoming calls, but remains on during Group Calls and All Calls. | To select a program, dial the program number (default 801 - 806, 8101 - 8132). The program is temporarily disconnected by outgoing and incoming calls, but remains on during Group Calls and All Calls. |
Revision as of 00:09, 18 December 2007
The AlphaCom system is prepared for distribution of audio programs. There must be an external audio source as input to each program, a radio, CD-player, alarm device or other sound input.
A number of inputs for audio programs are available, depending on the system configuration. By default 6 audio program inputs are available via the APC board for the AlphaCom E20 and AlphaCom E26, and 2 audio program inputs for the AlphaCom E7. The number of audio program inputs can be expanded by using AGA board.
Contents
Audio Program selection
To select a program, dial the program number (default 801 - 806, 8101 - 8132). The program is temporarily disconnected by outgoing and incoming calls, but remains on during Group Calls and All Calls.
To switch off a program, press the C-key or dial 800.
When lifting the handset the dialing tone is normally heard, replacing any program. To listen to the program with the handset off, simply hold the M-key down while lifting the receiver, and the dialing tone is not turned on.
Additional Information
- Each Program Distribution Board installed reduces the maximum number of subscribers in the system by 6.
- APF boards were earlier used for program distribution. They have been replaced by AGA boards.
- Priority Programs are not turned off during calls. (programmable per program).
Program Step
You can step through a list of available programs by dialing 790 on your station. Program off (800) is always included in the list. There are two alternative program step sequences: 3 or 6 programs.
The sequences are after autoload :
- Program 1, 2, 3, 4, 5, 6 and off.
- Program 1, 2, 3 and off.
- The number of programs in each sequence is programmable. The sequence setting is valid for the entire system.
- Each station can choose between sequence 1 or 2.
Program step codes:
- 790 - step up
- 791 - step down
- 792 - restore last
Program Priority
Program can be given 4 different priority levels affecting the program in the following way:
* low | the program is turned off during conversation. |
* medium and high | the program remains on during conversations. |
* alarm | activates the handset & volume override for InterGuard stations if the program is activated by remote set-up to Group. This is used to distribute an alarm message as a program. |
Turning on Programs at Other Stations
From selected stations, for example a control room station, you can remotely set up a program to another intercom station, or to a group of stations. To set up a program remotely to another station, dial 74, then the subscriber number and the program number. To set up a program to a group of subscribers, dial 75, the group number and the program number.
Additional Information
- It is possible to prevent stations from canceling programs.
- After a reset of the exchange, the program set-up is restored.
Software
- AMC 07.01 to prevent stations from canceling programs.