Revision as of 22:05, 26 November 2007
Event description
Event Owner: | A station or an UDP group |
Event type: | 13 - Faulty station line |
Subevent: | N/A |
When change to ON: | A station's line monitoring has found a problem or if the whole ASLT board becomes faulty |
When change to OFF: | A station's line monitoring has found the station OK |
When related to: | N/A |
Application
Switch over a PA-system to a standby circuit
Additional information
There is also a default "Faulty Line" event, which becomes active if one more stations are faulty. This event is used for general line error reporting. The reporting is configured from AlphaPro, Exchange & System -> RCI -> Faults: Faulty Line. Default setting is MST 1 0 28, which is by reporting line errors (28) to station 1.