Difference between revisions of "Faulty Station Line (Event Type)"
From Zenitel Wiki
(→Additional information) |
|||
Line 23: | Line 23: | ||
== Additional information == | == Additional information == | ||
+ | The faulty station event is reported On after reset of AlphaCom, if the station was removed during the reset. IP stations and SIP stations are reported faulted if not registered within 4-5 minutes after AlphaCom reset (and the station was registered before the reset). (Since AMCD 10.55, {{Bugzilla|204}}) | ||
+ | |||
There is also a default "Faulty Line" event, which becomes active if one more stations are faulty. This event is used for general line error reporting. The reporting is configured from AlphaPro, Exchange & System -> RCI -> Faults: Faulty Line. Default setting is [[MST - Mail to Station|MST]] 1 0 28, which is by reporting line errors (28) to station 1. | There is also a default "Faulty Line" event, which becomes active if one more stations are faulty. This event is used for general line error reporting. The reporting is configured from AlphaPro, Exchange & System -> RCI -> Faults: Faulty Line. Default setting is [[MST - Mail to Station|MST]] 1 0 28, which is by reporting line errors (28) to station 1. | ||
Revision as of 13:45, 28 May 2009
Event description
Event Owner: | A station or an UDP group |
Event type: | 13 - Faulty station line |
Subevent: | N/A |
When change to ON: | A station's line monitoring has found a problem or if the whole ASLT board becomes faulty |
When change to OFF: | A station's line monitoring has found the station OK |
When related to: | N/A |
Application
Switch over a PA-system to a standby circuit
Additional information
The faulty station event is reported On after reset of AlphaCom, if the station was removed during the reset. IP stations and SIP stations are reported faulted if not registered within 4-5 minutes after AlphaCom reset (and the station was registered before the reset). (Since AMCD 10.55, BZ 204)
There is also a default "Faulty Line" event, which becomes active if one more stations are faulty. This event is used for general line error reporting. The reporting is configured from AlphaPro, Exchange & System -> RCI -> Faults: Faulty Line. Default setting is MST 1 0 28, which is by reporting line errors (28) to station 1.