Difference between revisions of "Event Trigger (Event Type)"
From Zenitel Wiki
(→Subevents) |
(→Event description) |
||
Line 8: | Line 8: | ||
|'''Event type''': || 15 - Event trigger feature | |'''Event type''': || 15 - Event trigger feature | ||
|- | |- | ||
− | |'''Subevent''': || | + | |'''Subevent''': || See below |
|- | |- | ||
|'''When change to ON''': || When dialing a dirno with feat. 52, 85, 95 or 105 | |'''When change to ON''': || When dialing a dirno with feat. 52, 85, 95 or 105 |
Revision as of 18:05, 12 November 2007
Event description
Event Owner: | A station or UDP group |
Event type: | 15 - Event trigger feature |
Subevent: | See below |
When change to ON: | When dialing a dirno with feat. 52, 85, 95 or 105 |
When change to OFF: | When feature 95 or 105 disconnects |
When related to: | Mandatory. The event trigger directory number |
Event triggers
- - Feature 52 (9534): Event trigger without cancel tone
- - Feature 85 (9533): Event trigger with cancel tone
- - Feature 95 (9535): Event trigger with directory number parameter
- - Feature 105 (9545): Event trigger with digit parameter
Subevents
Feature 105: Subevent = digit pressed (and released). If subevent = 255, the macro %sev will return the dialled digit
Additional information
- - Feature 52 and 85 only triggers the ON event
Application
- - Any function or combination of functions which is not supported by the standard features in the AlphaCom