Revision as of 22:10, 9 January 2008
Event description
Event Owner: | A station or UDP group |
Event type: | 15 - Event trigger feature |
Subevent: | See below |
When change to ON: | When dialing a directory number with feature 52, 85, 95 or 105 |
When change to OFF: | When feature 95 or 105 disconnects |
When related to: | The event trigger directory number |
Event triggers
- Feature 52 (9534): Event trigger without cancel tone
- Feature 85 (9533): Event trigger with cancel tone
- Feature 95 (9535): Event trigger with directory number parameter
- Feature 105 (9545): Event trigger with digit parameter
Feature 52 and 85 triggers the ON event only
Subevents
- The parameter 1 of the Event Trigger directory number (52/n or 85/n) must match the sub-event
- Example: Feature 85/2 will trigger event type 15, sub-event 2
- The parameter 1 can be used to group event triggers by filtering on subevent type
Application
- Any function or combination of functions which is not supported by the standard features in the AlphaCom