Difference between revisions of "MPP - Mail to Pocket Pager"
From Zenitel Wiki
Line 1: | Line 1: | ||
{{A}} | {{A}} | ||
+ | <br> | ||
== Syntax == | == Syntax == | ||
Revision as of 09:12, 11 January 2017
Syntax
MPP <"pager-address"/pager-id> <source.phys.no> <"mail-text"/mail-id> [<beepcode>] [<no-transm>] [<prior>]
- Receiving pager:
- <pager-id> is configured pager number 1 - 600.
- Or the address of the pager receiver in "", in record type 1 of ESPA 4.4.4 message. Settings for pager number 1 is used. This option introduced in AMCD 10.52.
- <source.phys.no> is Physical number considered as sender of paging, used for filling in predefined mails. Not used for Free text mails, use 0.
- Text sent to pager (in record type 2 of ESPA 4.4.4 message)
- Mail text: Free text (maximum 128 characters) in quotes. (Prior AMCD 10.52 max 16 characters.)
- or a Predefined AlphaCom mails number
- <beepcode> : 0-9 Beep code sent to paging system, in record type 3 of ESPA 4.4.4 message.
- <no-transm> : 1, 2.. Number of transmissions, code sent to paging system, in record type 5 of ESPA 4.4.4 message.
- <prior> : 1 , 2 or 3: Priority sent to paging system, in record type 6 of ESPA 4.4.4. 1 = Alarm; 2 = High; 3 = Normal
Examples
MPP 2 0 "Temp. alarm" – Send text-message to pager 2 MPP "1024" 0 "Temp. alarm" – Send text-message to pager with address "1024" MPP 1 3 10 - Send Call-me message (10) from station 3 to pager 1