'''AMS''' is used to play prerecorded audio message to a single station.
'''AMS''' is used to play prerecorded audio message to a single station. The feature is using [[Volume Override]], and will play the massage at full volume.


=== Syntax ===
=== Syntax ===

Revision as of 12:04, 25 February 2015

AMS is used to play prerecorded audio message to a single station. The feature is using Volume Override, and will play the massage at full volume.

Syntax

AMS <phys.no> <alarm.no>
  • <phys.no> = The physical number of the station (1-552)
  • <alarm.no> = The index number of the audio message (1-80)


From software version 11.2.3.11:

AMS <phys.no> <alarm.no> <hvo>
  • <hvo> Optional parameter "handset volume override". 1 = on, 0 = off. Default = 1


Examples

AMS 23 2 – Alarm message 2 (8192) to station 23
AMS 23 0 – Alarm message OFF to station 23
AMS 23 2 0 – Alarm message 2 (8192) to station 23, without volume override