Difference between revisions of "Remote setup of Alarm message feature"
From Zenitel Wiki
(New page: '''68 FEAT_RC_ALARM_GR''' {| border="1" !style="background:#ffdead;"|Param1 !style="background:#ffdead;"|Description |- | ?? || Remote setup of alarm message to group of stations |- |colsp...) |
|||
Line 1: | Line 1: | ||
− | + | {| | |
− | {| | ||
− | |||
− | |||
|- | |- | ||
− | | | + | |width="170pt"|'''Feature''': |
+ | | Remote setup of Alarm Message | ||
+ | |- | ||
+ | |'''Default directory number''': || 761 | ||
+ | |- | ||
+ | |'''Feature number''': || 68 | ||
+ | |-valign="top" | ||
+ | |'''Parameter 1''': || 0 (N/A) | ||
+ | |-valign="top" | ||
+ | |'''Description''': || Remotely activate playback of [[alarm message]] at another station or group of stations. | ||
+ | Procedure: 761 + group + alarm message. | ||
+ | Examples: | ||
+ | * 761 + 85 + 8191 Turn on alarm message 8191 to stations in group 85 | ||
+ | * 761 + 85 + 8190 Turn off alarm message to stations in group 85 | ||
+ | |||
+ | The feature requires [[ASVP]] board. | ||
+ | |||
+ | *Alarm messages can also be triggered from the [[Event Handler]] or [[RCI]] by using the commands [[AMS]] or [[AMG]], or the [[ACDP|AlphaCom Data Protocol]] command [[ALARM MSG|$ALRM]] | ||
+ | |||
+ | |} | ||
+ | |||
+ | |||
|- | |- | ||
|colspan="2"|Play alarm message on group of stations. | |colspan="2"|Play alarm message on group of stations. |
Revision as of 16:41, 25 January 2008
Feature: | Remote setup of Alarm Message |
Default directory number: | 761 |
Feature number: | 68 |
Parameter 1: | 0 (N/A) |
Description: | Remotely activate playback of alarm message at another station or group of stations.
Procedure: 761 + group + alarm message. Examples:
The feature requires ASVP board.
|
|-
|colspan="2"|Play alarm message on group of stations.
Dial: <dir.no> <group dir.no>