== Description == | == Description == | ||
− | + | A [[group call]] can be configured to start audio without the need of pressing the M-key. The parameter is not supported in [[AlphaPro]], so it has to be changed in the nvram, either via the [[TST]] console or by using the [[Event Handler]]. | |
6 &003367 .ex_profile.group[1].flags = 1 (0x01) | 6 &003367 .ex_profile.group[1].flags = 1 (0x01) |
Revision as of 11:25, 9 May 2008
Description
A group call can be configured to start audio without the need of pressing the M-key. The parameter is not supported in AlphaPro, so it has to be changed in the nvram, either via the TST console or by using the Event Handler.
6 &003367 .ex_profile.group[1].flags = 1 (0x01)
Flags:<br\> 0 Regular group call behaviour. <br\> 1 will turn the Automatic M-key on for all stations initiating group call. <br\> 2 will turn it on only for SIP stations initiating group call. <br\>
Configuration from AlphaPro Event Handler
(Use System Status Event related to device 65 )
$SNV Q(flag) W1 W11 W(group number) W6
flag = 0 (off) 1 or 2 as described above.<br\>
group number = 1 - 100
Automatic M-key is meant to be used on SIP or special non display stations. Automatic M-key will on AlphaCom display stations show "wait" in second line of the display.