Difference between revisions of "IP Substation Indication LEDs"
From Zenitel Wiki
(New page: Indication LEDs STATION LED (on board and in front plate) Blinking 1 sec. interval Station does not have connection to the AlphaCom E exchange. Possible reasons: - No connection to Ether...) |
|||
Line 28: | Line 28: | ||
- Light 100 Mbit Ethernet connection | - Light 100 Mbit Ethernet connection | ||
- No light 10 Mbit Ethernet connection | - No light 10 Mbit Ethernet connection | ||
+ | |||
+ | [[Category: Stations]] | ||
+ | [[Category: IP Stations]] |
Revision as of 21:29, 10 October 2007
Indication LEDs STATION LED (on board and in front plate) Blinking 1 sec. interval Station does not have connection to the AlphaCom E exchange. Possible reasons: - No connection to Ethernet - Wrong AlphaCom E IP address configured - Invalid IP address - No or wrong gateway to the AlphaCom E exchange Blinking 5 sec. interval Station has connection to the AlphaCom E exchange, but has not been registered. Reason: - Station has not been programmed in AlphaPro No blinking Possible reasons: - Station connected and registered to the AlphaCom E exchange - All OK - Station not powered up (if no other LEDs are active) STATUS LED Blinking 2 red + 1 green Station does not have connection to the AlphaCom E exchange Blinking 1 red + 2 green Station has connection to AlphaCom E exchange, but has not been registered Blinking 3 green Station connected and registered in the AlphaCom E exchange LAN LEDs (on LAN and AUX RJ45-jacks): Left green LED: - Steady light Ethernet connection OK - Blinking Ethernet traffic - No light No Ethernet connection Right amber LED: - Light 100 Mbit Ethernet connection - No light 10 Mbit Ethernet connection