− | This error message indicates that the driver for the hardware dongle is not installed. The error message will be displayed regardless if the dongle is inserted in the PC or not. | + | This error message indicates that the driver for the hardware dongle (USB key) is not installed. The error message will be displayed regardless if the dongle is inserted in the PC or not. |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
After the AlphaPro installation has been installed by running the '''setup.exe''' file, the driver for hardware key must be installed separately. | After the AlphaPro installation has been installed by running the '''setup.exe''' file, the driver for hardware key must be installed separately. |
Revision as of 21:43, 21 November 2016
Problem
Error message "SuperPro initialization failed" or "RNBOsproInitialize Status = 12" when starting AlphaPro first time after installation.
Solution
This error message indicates that the driver for the hardware dongle (USB key) is not installed. The error message will be displayed regardless if the dongle is inserted in the PC or not.
After the AlphaPro installation has been installed by running the setup.exe file, the driver for hardware key must be installed separately.
- In the Start menu in Windows, open the folder Zenitel > AlphaPro
- Start "Launch Sentinel System Driver..."
- The driver will now be installed