Difference between revisions of "OPC Server - Release Notes"
From Zenitel Wiki
m (Text replacement - "<br\>" to "<br />") |
|||
Line 1: | Line 1: | ||
[[Category: Release notes]] | [[Category: Release notes]] | ||
+ | [[Category: OPC]] | ||
'''Release State:''' Released<br/> | '''Release State:''' Released<br/> |
Revision as of 10:47, 7 September 2017
Release State: Released
Release Version: 5.3.3.0
Installation Package: OPCServerSetup.msi
Contents
- 1 AlphaCom OPC Server 5.x.x.x
- 1.1 Important Note about Upgrading from version 5.0.x.x.
- 1.2 AlphaCom OPC Server 5.4.3.2 (2014-04-29)
- 1.3 AlphaCom OPC Server 5.4.3.1 (2014-03-28)
- 1.4 AlphaCom OPC Server 5.4.3.0 (2014-03-07)
- 1.5 AlphaCom OPC Server 5.3.3.0 (2013-01-24)
- 1.6 AlphaCom OPC Server 5.2.3.0 (2011-02-18)
- 1.7 AlphaCom OPC Server 5.2.3.1 (2011-05-09)
- 1.8 AlphaCom OPC Server 5.2.3.0 (2011-02-18)
- 1.9 AlphaCom OPC Server 5.1.3.2 (2011-01-04)
- 1.10 AlphaCom OPC Server 5.1.3.1 (2010-10-10)
- 1.11 AlphaCom OPC Server 5.1.3.0 (2010-09-17)
- 1.11.1 Functional Changes/Enhancements
- 1.11.1.1 BZ 227 OPC DA: No information available telling which station is A- and B-subscriber in a conversation
- 1.11.1.2 OPC DA: No information available seperating if station is in calling mode (private ringing) or in a conversation (connected)
- 1.11.1.3 BZ 420 From OPC it should be possible to send alarm messages to groups
- 1.11.2 Errors Corrected
- 1.11.2.1 BZ 362 OPC DA: Tone Test errors are not reported by the Linestate item
- 1.11.2.2 BZ 330 AE: Some events are not reported on the selected format
- 1.11.2.3 DA: Only output.1 for IP stations is working output.2 and .3 do not work
- 1.11.2.4 BZ 406 OPC Server Windows 7 Compatible (64 bit)
- 1.11.2.5 DA: Only up 255 stations was reported in the OPC DA item tree.
- 1.11.1 Functional Changes/Enhancements
- 2 AlphaCom OPC Server 5.0.0.0 (2009-07-01)
- 3 AlphaCom OPC Server 4.1.0.0 (2009-04-01)
- 4 AlphaCom OPC Server 4.0.0.0 (2008-10-29)
AlphaCom OPC Server 5.x.x.x
Important Note about Upgrading from version 5.0.x.x.
Due to bug "BZ 406 OPC Server Windows 7 Compatible", and good programming practices, the location of the OPCServer configuration file needed to be moved from Program Data Folder to Application Data Folder.
It is not implemented any automatic transfer of the configuration file, so after an upgrade either the old config files needs to copied manually to its new location, or the configuration needs to be re-done with the new AlphaComOPCConfigurator tool (v 2.1.3.0).
Note! After a manual copy the configuration should be verified in the new AlphaComOPCConfigurator tool.
AlphaCom OPC Server 5.4.3.2 (2014-04-29)
Errors Corrected
MTN-495: OPC node status not updated when multiple nodes are involved in AlphaNet
Incorrect Node status and node behavior for Alphanets with eight or more nodes.
AlphaCom OPC Server 5.4.3.1 (2014-03-28)
Errors Corrected
MTN-486: Can not delete Call requests after some runtime
Issue with Signed Mailtag references causes failing of deleting mailtags with value greater then 32768. This issue with signed integers in OPC server could also potentially give problem with other OPC features where large numbers are involved.
AlphaCom OPC Server 5.4.3.0 (2014-03-07)
Functional Enhancements
Added SmartInspect log events
Use OPCConfigurator Tool to configure log file name, or use SmartInspect Log Viewer to connect directly to OPC server in run time and view logs.
Download Redistributable Console
Errors Corrected
MTN-479: OPC AE: Custom format fails on CallRequest Synchronization events
The Custom format for "Call Request" from OPCConfigurator Tool works only for new events. Synchronization of event during OPC connect time, or when writing '0' to the DA .synchronized item will send CallRequest events with default format.
MTN-439: Sending of OPC Event Stops
Sending of all OPC Events may stop if OPC Client request Call Request Items in same time as Call Request being updated from AlphaCom
AlphaCom OPC Server 5.3.3.0 (2013-01-24)
Functional Enhancements
MTN-49: OPC Server support for IP-ARIO and Turbine
Number of inputs and outputs updated for stations type IP-ARIO and Turbine Compact Stations. For IP-ARIO also tags are added for statusflags, ackfault and clearfault.
MTN-142: OPC: Uses old version of DANSrvAE.exe
Advosol OPC server toolkit updated to latest version 7.0.0.0. Some bug fixes and memory issues fixes.
New OPC DA tag now also show the version of the Advosol toolkit used: AlphaComOPCServer.AdvosolVersion.
Latest OPC Core Components from OPC Foundation can be used for this release. A download link for OPC Core Components is added to is the "AlphaCom OPC Configurator Tool" in the "About" tab.
Errors Corrected
MTN-53: OPC Configurator: Using node "0" gives problems
Node 0 was originally used for simple configuration when only connecting to 1 (local) node. The Node 0 features is not compatible with other updates in the OPC project. Possibility to program node 0 in OPC Configurator is removed.
AlphaCom OPC Server 5.2.3.0 (2011-02-18)
Functional Enhancements
AlphaCom OPC Server 5.2.3.1 (2011-05-09)
Errors Corrected
BZ 541: Station item "Operational" is not reporting "0" when station is disconnected
AlphaCom OPC Server 5.2.3.0 (2011-02-18)
Functional Enhancements
Added new station OPC item .customparameter1
The parameter will enable sending of a custom parameter (16 bit int) from the evnethandler programmed in AlphaPro. E.g. @01C7 M7F01 L(1)101 U0 W1200 W0 W0 W0 W0
AlphaCom OPC Server 5.1.3.2 (2011-01-04)
Functional Enhancements
New Informational log Event: Connecting to AlphaCom {ip}/{port}
AlphaCom OPC Server 5.1.3.1 (2010-10-10)
Errors Corrected
AE: Custom text format do not work for OPC AE Events (Only default custom texts is used)
AlphaCom OPC Server 5.1.3.0 (2010-09-17)
Old Configuration file:
C:\Program Files\STENTOFON\AlphaCom OPC Server\Stentofon.AlphaCom.AlphaNet.Config.OPC.xml
The location of the new configuration file depends on OS version and other enviromnet setups (using variable Environment.SpecialFolder.ApplicationData).
Typical locations:
WinXP: C:\Documents and Settings\{username}\Application Data\Stentofon\SDK\Stentofon.AlphaCom.AlphaNet.Config.OPC.xml Win7 : C:\Users\{username}\AppData\Roaming\Stentofon\SDK\Stentofon.AlphaCom.AlphaNet.Config.OPC.xml
Functional Changes/Enhancements
BZ 227 OPC DA: No information available telling which station is A- and B-subscriber in a conversation
New tag .callapri, see Station Item Table
OPC DA: No information available seperating if station is in calling mode (private ringing) or in a conversation (connected)
New tag .callmode, see Station Item Table
BZ 420 From OPC it should be possible to send alarm messages to groups
Added new nodeX.groups.gx node tree, see Node Item Table
Errors Corrected
BZ 362 OPC DA: Tone Test errors are not reported by the Linestate item
New item .tonetest added for indication tonetest errors (The linestate can be OK even if tonetest error) See Station Item Table
BZ 330 AE: Some events are not reported on the selected format
DA: Only output.1 for IP stations is working output.2 and .3 do not work
BZ 406 OPC Server Windows 7 Compatible (64 bit)
* For 64 bit OSs it is required to install the "Advosol OPC Core Components" included in the new Setup package * The Config file is moved to the "Application Data Folder". * Securtiy exeption when creating new Event Log Source "AlphaComOPCServer" resolved with new function in the AlphaComOPCConfigurator to create the source (requires "run as Admininstrator")
DA: Only up 255 stations was reported in the OPC DA item tree.
Now the maximum of stations is 1000 (practical available is 552)
AlphaCom OPC Server 5.0.0.0 (2009-07-01)
Functional Changes/Enhancements
Major changes
- Re-written to use the new Stentofon.AlphaCom.AlphaNet.dll library.
- Config file name and format is changed with the new library. New config file name: Stentofon.AlphaCom.AlphaNet.OPC.xml
The OPCServerConfigurator application will test for old config file, and prompt for automatic conversion to the new format. - Implemented Redundant OPC Server mode allowing two OPC Devices connect to the same AlphaCom nodes. Requires AlphaCom Sys version 10.55
- The station item .relatedto is now updated on AlphaCom CallStatus event. The .relatedto property will then be set on calls in private mode, before the call is accepted.
Easy Projects Activities
Activity | Short Description |
---|---|
209 | Make (IP) station IO items based on ST_STATE messages, make RCO/RCI item obsolete |
210 | Make global node RCI based on RCI_CHANGED messages incl OPC/RCI config |
211 | Implemented OPC Items for M-Key, C-Key and DAK-key |
217 | Updated to use library Stentofon.AlphaCom.AlphaNet.dll |
166 | Redundant OPC Server |
Limitations
Global RCI/RCO states is updated on state changes, but is not synchronized at OPC Server startup.
Errors Corrected
Easy Projects Activities
Activity | Short Description |
---|---|
205 | cr_iterate_command items offset |
206 | OPC AE: "Station UP" is reported on all ST_STATE changes |
AlphaCom OPC Server 4.1.0.0 (2009-04-01)
Functional Changes/Enhancements
Added the OPC AE event StationSignal (.signal).
This event is generated from the station sending a Call Request ("I need attention")
AlphaCom OPC Server 4.0.0.0 (2008-10-29)
First official Release