The '''%prci''' macro is used in the [[Event Handler]] to check state of a physical input on a IP-ARIO.
The '''%prci''' macro is used in the [[Event Handler]] to check state of a physical input on an IP Station or IP-ARIO.


===Syntax===
===Syntax===
Line 15: Line 15:
[[Category:Event Handler macros]]
[[Category:Event Handler macros]]
[[Category:Event Handler]]
[[Category:Event Handler]]
[[Category: RCI]]
[[Category: IP-ARIO]]
[[Category: IP-ARIO]]

Revision as of 07:15, 18 May 2016

The %prci macro is used in the Event Handler to check state of a physical input on an IP Station or IP-ARIO.

Syntax

%prci(station,input_no)

Return 1/0 state of a physical input

  • station: Physical number 1 - 552
  • input_no: Input number 1 - 8

Examples

%prci(5,1)           - Return state of input 1 on station 5

Back to Event_Handler#List_of_context_parameters.