Actions

Difference between revisions of "INCA Station Restore Factory Defaults"

From Zenitel Wiki

(Restore to Factory Default for IP Stations without Display)
Line 3: Line 3:
 
* IP Substations - [[Weather and Vandal Resistant IP Substation - 1008041100|1008041100]]/[[Weather and Vandal Resistant IP Substation for 3 gang Back Box - 1008051000|1008051000]]
 
* IP Substations - [[Weather and Vandal Resistant IP Substation - 1008041100|1008041100]]/[[Weather and Vandal Resistant IP Substation for 3 gang Back Box - 1008051000|1008051000]]
 
* IP Video Door Stations - [[IP Video Door Station - 1401110100|1401110100]]/[[IP Video Door Station - 1401110200|1401110200]]
 
* IP Video Door Stations - [[IP Video Door Station - 1401110100|1401110100]]/[[IP Video Door Station - 1401110200|1401110200]]
 +
[[File:Load Defaults without Display - 1.PNG|right|300px]]
  
 
This procedure is also applicable for the kits. This requires that a push button is connected between pin 1 and pin 4 on connector P4.
 
This procedure is also applicable for the kits. This requires that a push button is connected between pin 1 and pin 4 on connector P4.
Line 8: Line 9:
 
* The [[IP Substation Kit - 1008090200]]
 
* The [[IP Substation Kit - 1008090200]]
 
[[File:Load Defaults without KEY.PNG|left|thumb|300px|Kits require a push button to be connected between pins 1 and 4]]
 
[[File:Load Defaults without KEY.PNG|left|thumb|300px|Kits require a push button to be connected between pins 1 and 4]]
 
+
[[File:Load Defaults without Display - 2.PNG|right|300px]]
 
The unit can be set to use either '''Static IP''' or '''DHCP'''. Pay attention to the call LED during the restore procedure:
 
The unit can be set to use either '''Static IP''' or '''DHCP'''. Pay attention to the call LED during the restore procedure:
 
# While pressing the call button, power up the station and keep the button pressed.
 
# While pressing the call button, power up the station and keep the button pressed.
Line 21: Line 22:
 
*Username: '''admin'''
 
*Username: '''admin'''
 
*Password: '''alphaadmin'''
 
*Password: '''alphaadmin'''
 
--------------
 
 
An IP Station may have to be reset to its original factory default settings if, for instance, the password to the webserver is forgotten.
 
 
The defaults can be either be set to Static IP or Activated DHCP (when there are many new IP Substations in an installation).
 
 
 
 
[[File:Load Defaults without Display - 1.PNG|right|300px]]
 
 
 
[[File:Load Defaults without Display - 2.PNG|right|300px]]
 
  
  

Revision as of 16:47, 17 March 2017

APS.png

This procedure is applicable for the stations:

Load Defaults without Display - 1.PNG

This procedure is also applicable for the kits. This requires that a push button is connected between pin 1 and pin 4 on connector P4.

Kits require a push button to be connected between pins 1 and 4
Load Defaults without Display - 2.PNG

The unit can be set to use either Static IP or DHCP. Pay attention to the call LED during the restore procedure:

  1. While pressing the call button, power up the station and keep the button pressed.
  2. Release the button after exactly 2 flashes of the LED.
  3. Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
  4. Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
  5. Release the button and the station will restart with the factory default settings.

Factory default values:

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100 or DHCP
  • Username: admin
  • Password: alphaadmin



* Software 01.06 and earlier: ADMIN/alphacom)