Actions

Difference between revisions of "INCA Station Restore Factory Defaults"

From Zenitel Wiki

Line 7: Line 7:
 
[[File:Load Defaults without KEY.PNG|left|thumb|300px|Kits require a push button to be connected between pins 1 and 4]]
 
[[File:Load Defaults without KEY.PNG|left|thumb|300px|Kits require a push button to be connected between pins 1 and 4]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
'''Procedure:'''
+
'''Procedure:'''<br>
 
When loading factory defalt settings, the unit can be set to use either '''Static IP''' or '''DHCP'''.  
 
When loading factory defalt settings, the unit can be set to use either '''Static IP''' or '''DHCP'''.  
 
[[File:Load Defaults without Display - 1.PNG|right|200px]]
 
[[File:Load Defaults without Display - 1.PNG|right|200px]]
Line 17: Line 17:
 
# Release the button and the station will restart with the factory default settings.
 
# Release the button and the station will restart with the factory default settings.
  
Factory default values:
+
'''Factory default values:'''
 
*Station Mode: '''Pulse'''
 
*Station Mode: '''Pulse'''
 
*Station IP address: '''169.254.1.100''' or '''DHCP'''
 
*Station IP address: '''169.254.1.100''' or '''DHCP'''

Revision as of 16:56, 17 March 2017

APS.png

This procedure is applicable for the stations:

Kits require a push button to be connected between pins 1 and 4


Procedure:
When loading factory defalt settings, the unit can be set to use either Static IP or DHCP.

Load Defaults without Display - 1.PNG
Load Defaults without Display - 2.PNG
  1. While pressing the call button, power up the station and keep the button pressed.
  2. Release the button after exactly 2 flashes of the LED.
  3. Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
  4. Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
  5. Release the button and the station will restart with the factory default settings.

Factory default values:

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100 or DHCP
  • Username: admin
  • Password: alphaadmin



* Software 01.06 and earlier: Username/password isADMIN/alphacom