Actions

Difference between revisions of "INCA Station Kit Restore Factory Defaults"

From Zenitel Wiki

Line 1: Line 1:
 +
{{APS}}
 +
This procedure is applicable for:
 +
* IP Substation Kit - [[IP Substation Kit - 1008090200|1008090200]]
 +
* IP Master Station Kit [[IP Master Station Kit - 1008093000|100809300]]
 +
 +
The unit can be set to use either '''Static IP''' or '''DHCP'''. On the rear side of the PCB there is a red status LED. Pay attention to this LED during the restore procedure:
 +
 +
[[File:Load Defaults without KEY.PNG|right|thumb|800px|Connect a push button between pins 1 and 4]]
 +
 +
# Connect a push button ('''KEY1''') between pin 1 and 4 on the P4 connector.
 +
# While pressing the button, power up the station kit and keep the button pressed.
 +
# Release the button '''after exactly 2 flashes''' of the LED.
 +
# Let the LED flash for '''exactly 2 more times''' (Static IP) or '''exactly 4 more times''' (DHCP), then press the button again.
 +
# Keep the button pressed until the LED '''flashes fast 2 time'''s (Static IP) or '''flashes fast 4 times''' (DHCP) indicating a successful reset.
 +
# Release the button and the station will restart with the factory default settings.
 +
 +
Factory default values:
 +
*Station Mode: '''Pulse'''
 +
*Station IP address: '''169.254.1.100''' or '''DHCP'''
 +
*Username: '''admin'''
 +
*Password: '''alphaadmin'''
 +
 +
 +
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]
 +
 +
 +
 
{{APS}}This procedure is applicable for:
 
{{APS}}This procedure is applicable for:
* IP Master Station Kit [[IP Master Station Kit - 1008093000|100809300]]
+
 
* IP Substation Kit - [[IP Substation Kit - 1008090200|1008090200]]
 
 
* [[IP Heavy Duty Station|IP Heavy Duty station 1008072xx0]]
 
* [[IP Heavy Duty Station|IP Heavy Duty station 1008072xx0]]
  

Revision as of 13:26, 17 March 2017

APS.png

This procedure is applicable for:

The unit can be set to use either Static IP or DHCP. On the rear side of the PCB there is a red status LED. Pay attention to this LED during the restore procedure:

Connect a push button between pins 1 and 4
  1. Connect a push button (KEY1) between pin 1 and 4 on the P4 connector.
  2. While pressing the button, power up the station kit and keep the button pressed.
  3. Release the button after exactly 2 flashes of the LED.
  4. Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
  5. Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
  6. Release the button and the station will restart with the factory default settings.

Factory default values:

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100 or DHCP
  • Username: admin
  • Password: alphaadmin


APS.png

This procedure is applicable for:


The Factory Default can be either set to Static IP 169.254.1.100 or activate DHCP.

Connect a push button (KEY1) between pin 1 and 4 on the P4 connector.

Load Defaults without KEY.PNG


Restore with Static IP

  1. While pressing the button, power up the station kit.
  2. When the station kit LED starts blinking, release the button after exactly 2 blinks.
  3. Let the LED blink for exactly 2 more times, then press the button again.
  4. Keep the button pressed until the LED blinks fast 2 times indicating a successful reset with static IP.
  5. Release the button and the station kit will restart with the factory default settings.

Factory default values:

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100
  • Username: admin
  • Password: alphaadmin

Restore with Activated DHCP

The DHCP option is available from software version 01.07.

  1. While pressing the button, power up the station kit.
  2. When the station kit LED starts blinking, release the button after exactly 2 blinks.
  3. Let the LED blink for exactly 4 more times, then press the button again.
  4. Keep the button pressed until the LED blinks fast 4 times indicating a successful reset with activated DHCP.
  5. Release the button and the station kit will restart with the factory default settings.

Factory default values:

  • Station Mode: Pulse
  • Station IP address: From DHCP server
  • Username: admin
  • Password: alphaadmin