Actions

Difference between revisions of "Flowire"

From Zenitel Wiki

Line 7: Line 7:
 
* FCDC2 (1008080210) - without [[PoE]] - [https://www.zenitel.com/printpdf/product/fcdc2 datasheet]
 
* FCDC2 (1008080210) - without [[PoE]] - [https://www.zenitel.com/printpdf/product/fcdc2 datasheet]
 
   
 
   
 +
 +
== Factory defaults ==
 +
* Static IP address : 169.254.1.10
 +
* DHCP enabled. If obtain an dynamic address, it comes in addition to the static address.
 +
* NMK Password: HomePlugAV0123
 +
 
== Reset to Factory defaults ==
 
== Reset to Factory defaults ==
 
Flowire can be reset to Factory defaults by pressing the button for 15 seconds. The recessed button is located next to the Ethernet connector.  
 
Flowire can be reset to Factory defaults by pressing the button for 15 seconds. The recessed button is located next to the Ethernet connector.  
  
 
[[Category: Flowire]]
 
[[Category: Flowire]]

Revision as of 13:43, 1 March 2017

Flowire is based on the HomePlug AV power line communications specification, only using 24 - 48 V DC as the medium. It is a network bridge between Ethernet and a PLC link.

FCDC1.jpg

There are two variants


Factory defaults

  • Static IP address : 169.254.1.10
  • DHCP enabled. If obtain an dynamic address, it comes in addition to the static address.
  • NMK Password: HomePlugAV0123

Reset to Factory defaults

Flowire can be reset to Factory defaults by pressing the button for 15 seconds. The recessed button is located next to the Ethernet connector.