Actions

Difference between revisions of "INCA Station Restore Factory Defaults"

From Zenitel Wiki

Line 5: Line 5:
 
* [[IP Master Station Kit - 1008093000]] - A push button must be connected between pin 1 and pin 4 on connector P4.
 
* [[IP Master Station Kit - 1008093000]] - A push button must be connected between pin 1 and pin 4 on connector P4.
 
* The [[IP Substation Kit - 1008090200]] - A push button must be connected between pin 1 and pin 4 on connector P4.
 
* The [[IP Substation Kit - 1008090200]] - A push button must be connected between pin 1 and pin 4 on connector P4.
<div style="text-align:right;"> <youtube width="300" height="180">hZkqvww2ub0</youtube>  </div>
+
<div style="text-align:left;"> <youtube width="300" height="180">hZkqvww2ub0</youtube>  </div>
 
<br>
 
<br>
<div style="text-align:right;"> <youtube width="300" height="180">-RDBOLvI-lo</youtube>  </div>
+
<div style="text-align:left;"> <youtube width="300" height="180">-RDBOLvI-lo</youtube>  </div>
  
 
[[File:Load Defaults without KEY.PNG|left|thumb|300px|Kits require a push button to be connected between pins 1 and 4]]
 
[[File:Load Defaults without KEY.PNG|left|thumb|300px|Kits require a push button to be connected between pins 1 and 4]]

Revision as of 14:42, 3 May 2018

APS.png

This procedure is applicable for the stations:


Kits require a push button to be connected between pins 1 and 4


Procedure:
When loading factory defalt settings, the unit can be set to use either Static IP or DHCP.

Load Defaults without Display - 1.PNG


Load Defaults without Display - 2.PNG
  1. While pressing the call button, power up the station and keep the button pressed.
  2. Release the button after exactly 2 flashes of the LED.
  3. Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
  4. Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
  5. Release the button and the station will restart with the factory default settings.

Factory default values:

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100 (Static) or DHCP
  • Username: admin
  • Password: alphaadmin


Note icon Software 01.06 and earlier: Username/password is ADMIN/alphacom