Difference between revisions of "INCA Station Restore Factory Defaults"
From Zenitel Wiki
(→Preparations of Station kit) |
|||
Line 12: | Line 12: | ||
== Preparations of Station kit == | == Preparations of Station kit == | ||
Station kits require a push button to be connected between pins 1 and 4 | Station kits require a push button to be connected between pins 1 and 4 | ||
− | [[File:Load Defaults without KEY.PNG|left|thumb| | + | [[File:Load Defaults without KEY.PNG|left|thumb|400px|Push button between pin 1 (KEY1) and pin 4 (COM)]] |
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
Revision as of 15:30, 3 May 2018
Contents
Applicable for stations
- IP Substations - 1008041100/1008051000
- IP Video Door Stations - 1401110100/1401110200
- IP Master Station Kit - 1008093000 - A push button must be connected between pin 1 and pin 4 on connector P4.
- The IP Substation Kit - 1008090200 - A push button must be connected between pin 1 and pin 4 on connector P4.
Preparations of Station kit
Station kits require a push button to be connected between pins 1 and 4
Procedure
When loading factory defalt settings, the unit can be set to use either Static IP or DHCP.
- While pressing the call button, power up the station and keep the button pressed.
- Release the button after exactly 2 flashes of the LED.
- Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
- Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
- Release the button and the station will restart with the factory default settings.
Factory default values
- Station Mode: Pulse
- Station IP address: 169.254.1.100 (Static) or DHCP
- Username: admin
- Password: alphaadmin