This article describes how to configure the [[IP-LCM|IP-LCM Module]] when used with an AlphaCom server. | |||
== Inputs == | == Inputs == | ||
The [[IP-LCM|IP-LCM module]] has in total 14 inputs: | The [[IP-LCM|IP-LCM module]] has in total 14 inputs: | ||
| Line 10: | Line 11: | ||
* The six inputs on the TKIS-2 module are triggered by connecting the Input to GND. | * The six inputs on the TKIS-2 module are triggered by connecting the Input to GND. | ||
* Depending on switch settings the eight inputs on the IP-LCM board are triggerd either by a close contact (default), or by a DC voltage signal. See [[IP-LCM Connections]] for details. | * Depending on switch settings the eight inputs on the IP-LCM board are triggerd either by a close contact (default), or by a DC voltage signal. See [[IP-LCM Connections]] for details. | ||
* The IP-LCM is configured in the same way as other Turbine devices, see [[Turbine Configuration - AlphaCom mode|Turbine configuration]] <br> | |||
* The 8 inputs of the IP-LCM module are triggering [[Station DAK key as RCI (Event Type)|event 30]], DAK/Input 18-25. See [[RCI_-_Remote_Contol_Input#Inputs_from_IP_Stations.2FDevices|RCI configuration]] | |||
* The 8 relays must be mapped to RCO pins 17-24, see [[RCO - Remote Control Output]] | |||
Revision as of 12:30, 17 April 2019
This article describes how to configure the IP-LCM Module when used with an AlphaCom server.
Inputs
The IP-LCM module has in total 14 inputs:
- 6 inputs on the The TKIS-2 module itself
- 8 inputs on the IP-LCM board
- The six inputs on the TKIS-2 module are triggered by connecting the Input to GND.
- Depending on switch settings the eight inputs on the IP-LCM board are triggerd either by a close contact (default), or by a DC voltage signal. See IP-LCM Connections for details.
- The IP-LCM is configured in the same way as other Turbine devices, see Turbine configuration
- The 8 inputs of the IP-LCM module are triggering event 30, DAK/Input 18-25. See RCI configuration
- The 8 relays must be mapped to RCO pins 17-24, see RCO - Remote Control Output