Difference between revisions of "Flowire"
From Zenitel Wiki
m (Tag: Visual edit) |
|||
Line 4: | Line 4: | ||
There are two variants: | There are two variants: | ||
− | * [[FCDC-1]] (1008080110 ) - Forwards power to the spare pairs of the Ethernet port | + | |
− | * [[FCDC-2]] (1008080210) - Does not forward power to the Ethernet port | + | *[[FCDC-1]] (1008080110 ) - Forwards power to the spare pairs of the Ethernet port |
− | {{note|The FCDC-1 is directly forwarding the power from the Power Supply Unit to the Ethernet port. It is '''not''' using [[PoE]] (Power over Ethernet) technology}} | + | *[[FCDC-2]] (1008080210) - Does not forward power to the Ethernet port |
− | == Factory defaults == | + | {{note|The FCDC-1 is directly forwarding the power from the Power Supply Unit to the Ethernet port (802.3af Type 1 mode B only). This means it is using the spare pairs only for power, and there is no auto-sensing of polarity or load. It is '''not''' using [[PoE]] (Power over Ethernet) technology}} |
− | * Static IP address : '''169.254.1.10''' | + | ==Factory defaults== |
− | * DHCP enabled. If the unit obtains a dynamic IP address, it comes in addition to the static address. | + | |
− | * NMK Password: '''HomePlugAV0123''' | + | *Static IP address : '''169.254.1.10''' |
+ | *DHCP enabled. If the unit obtains a dynamic IP address, it comes in addition to the static address. | ||
+ | *NMK Password: '''HomePlugAV0123''' | ||
MAC address range: 00:13:CB:0A:00:00 -> 00:13:CB:0A:80:00 | MAC address range: 00:13:CB:0A:00:00 -> 00:13:CB:0A:80:00 | ||
Line 16: | Line 18: | ||
<br><br> | <br><br> | ||
− | == Reset to Factory defaults == | + | ==Reset to Factory defaults== |
Flowire can be reset to Factory defaults by pressing the button for 15 seconds. The recessed button is located next to the Ethernet connector. | Flowire can be reset to Factory defaults by pressing the button for 15 seconds. The recessed button is located next to the Ethernet connector. | ||
<br><br> | <br><br> | ||
− | == Related Information == | + | ==Related Information== |
− | |||
− | |||
+ | *[https://www.zenitel.com/product/fcdc2 Additional Documentation on Zenitel.com] | ||
[[Category: Flowire]] | [[Category: Flowire]] |
Revision as of 10:37, 23 December 2019
Flowire is based on the HomePlug AV power line communications specification, only using 24 - 48 V DC as the medium. It is a network bridge between Ethernet and a PLC link.
There are two variants:
- FCDC-1 (1008080110 ) - Forwards power to the spare pairs of the Ethernet port
- FCDC-2 (1008080210) - Does not forward power to the Ethernet port
The FCDC-1 is directly forwarding the power from the Power Supply Unit to the Ethernet port (802.3af Type 1 mode B only). This means it is using the spare pairs only for power, and there is no auto-sensing of polarity or load. It is not using PoE (Power over Ethernet) technology |
Factory defaults
- Static IP address : 169.254.1.10
- DHCP enabled. If the unit obtains a dynamic IP address, it comes in addition to the static address.
- NMK Password: HomePlugAV0123
MAC address range: 00:13:CB:0A:00:00 -> 00:13:CB:0A:80:00
Reset to Factory defaults
Flowire can be reset to Factory defaults by pressing the button for 15 seconds. The recessed button is located next to the Ethernet connector.