Difference between revisions of "Tamper switch"
From Zenitel Wiki
Line 1: | Line 1: | ||
− | {{ | + | {{AEIPS}} |
+ | The Turbine IP Substation has the possibilty to be fitted with a tamper switch. Making it possible to raise an alarm if the station is dismounted from the backbox. | ||
+ | [[file:1008091010.png|200px|thumb|Tamper Switch<br>(100 8091 010)]] | ||
+ | |||
== Configuration == | == Configuration == | ||
In [[AlphaPro]], create this event for the Tamper Switch: | In [[AlphaPro]], create this event for the Tamper Switch: |
Revision as of 11:08, 27 March 2020
The Turbine IP Substation has the possibilty to be fitted with a tamper switch. Making it possible to raise an alarm if the station is dismounted from the backbox.
Configuration
In AlphaPro, create this event for the Tamper Switch:
The IP Substation must have I/O 3 defined as an input, which is the default setting.
Mounting
Mounting instruction on Tamper Switch for IP Vandal Resistant Substation TKIE
Step 1: Remove the two nylon nuts shown below
Step 2: Attach the supplied spacers
Step 3: Mount the tamper switch board
Step 4: Move the button GND wire from the the TKIE board to the tamper switch board
Step 5: Use the supplied wires to connect GND and Input 3 as shown below