{{APS}}[[file:1008091010.png|200px|thumb|Tamper Switch<br>(100 8091 010)]]
+
{{AEIPS}}
 +
The Turbine IP Substation has the possibilty to be fitted with a tamper switch. Making it possible to raise an alarm if the station is dismounted from the backbox.
 +
[[file:1008091010.png|200px|thumb|Tamper Switch<br>(100 8091 010)]]
 +
 
 
== Configuration ==
 
== Configuration ==
 
In [[AlphaPro]], create this event for the Tamper Switch:
 
In [[AlphaPro]], create this event for the Tamper Switch:

Revision as of 11:08, 27 March 2020

AEIPS.png

The Turbine IP Substation has the possibilty to be fitted with a tamper switch. Making it possible to raise an alarm if the station is dismounted from the backbox.

Tamper Switch
(100 8091 010)

Configuration

In AlphaPro, create this event for the Tamper Switch:

Event handler configuration


The IP Substation must have I/O 3 defined as an input, which is the default setting.

Advanced AlphaCom -> I/O Settings


Mounting

Mounting instruction on Tamper Switch for IP Vandal Resistant Substation TKIE

Step 1: Remove the two nylon nuts shown below

Tamper1.png


Step 2: Attach the supplied spacers

Tamper2.png


Step 3: Mount the tamper switch board

Tamper3.png


Step 4: Move the button GND wire from the the TKIE board to the tamper switch board

Tamper4.png


Tamper5.png


Step 5: Use the supplied wires to connect GND and Input 3 as shown below

Tamper6.png