Actions

Difference between revisions of "INCA Video Desk Station LED Indicators"

From Zenitel Wiki

(Station LED)
 
Line 4: Line 4:
 
<br style="clear:both;" />
 
<br style="clear:both;" />
 
'''Blinking at 1 second intervals:'''<br/>
 
'''Blinking at 1 second intervals:'''<br/>
Station has no connection to the ICX-AlphaCom Server.
+
Station cannot register to the server/controller
  
 
Possible reasons:
 
Possible reasons:
* No connection to Ethernet
+
* Invalid network settings (IP address and network mask) in the device
* Wrong AlphaCom IP address configured
+
* Wrong or missing account settings (Server IP, directory number, password..)
* Invalid IP address
+
* Failing to register due to missing license in the server
* No gateway or wrong gateway to the ICX-AlphaCom Server
+
* The server is offline
 +
* Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP)
 +
If the server is on a different subnet, check that
 +
* A valid Default gateway is defined
 +
 
 +
'''No blinking:'''
 +
 
 +
Possible reasons:
 +
* Station connected and registered to the server/controller
 +
* Station not powered up (if no other LEDs are active)
  
 
'''Blinking at 5 second intervals:'''<br/>
 
'''Blinking at 5 second intervals:'''<br/>
Station connected but NOT registered in the ICX-AlphaCom Server.
+
{{Note| This LED behaviour only applies in ICX-AlphaCom mode}}
 +
Station connected but NOT registered in the ICX-AlphaCom
  
 
Possible reasons:  
 
Possible reasons:  
 
* Station has not been programmed in AlphaPro
 
* Station has not been programmed in AlphaPro
* Missing IP Station license in ICX-AlphaCom Server
+
* Missing IP Station license in ICX-AlphaCom
  
'''No blinking:'''
+
[[Category:Station Indication LEDs]]
 
 
Possible reasons:
 
* Station connected and registered to the ICX-AlphaComo Server
 
* Station not powered up (if no other LEDs are active)
 
  
 
=Display Color Bar=
 
=Display Color Bar=

Latest revision as of 11:44, 20 November 2020

Station LED

LED4 - Red 5mm LED on board rear side, also seen through front plate.

Station LED


Blinking at 1 second intervals:
Station cannot register to the server/controller

Possible reasons:

  • Invalid network settings (IP address and network mask) in the device
  • Wrong or missing account settings (Server IP, directory number, password..)
  • Failing to register due to missing license in the server
  • The server is offline
  • Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP)

If the server is on a different subnet, check that

  • A valid Default gateway is defined

No blinking:

Possible reasons:

  • Station connected and registered to the server/controller
  • Station not powered up (if no other LEDs are active)

Blinking at 5 second intervals:

Note icon This LED behaviour only applies in ICX-AlphaCom mode


Station connected but NOT registered in the ICX-AlphaCom

Possible reasons:

  • Station has not been programmed in AlphaPro
  • Missing IP Station license in ICX-AlphaCom

Display Color Bar

In the LCD display there is a bar color indicating the connection status:

  • Yellow indicates that the IP Desktop Station is connected to the server.
  • Green indicates an active, incoming or outgoing call.
  • Red indicates that no network connection can be established. If an Ethernet cable is connected the IP Video Display should connect automatically during start up.
  • Yellow-Red flashing indicates that no connection to the server can be established. If the server and the IP Desktop Station is configured correctly the connection is established automatically during start up. (May take some time)