Latest revision as of 10:04, 30 June 2022
Station configuration
Configure the IP Substation
- Perform a "Factory Default" setting on the IP Substation:
- Press the call button
- While the button is pressed, connect the IP Substation to the PoE switch
- Wait until the call LED of the station has flashed two times
- Release the call button and wait for two new flashes
- Push the button briefly after the two flashes
- Assign the PC an IP address in the range 169.254.x.x
- Connect the PC to the network switch
- On the PC start a web browser, and enter the IP station address 169.254.1.100 in the address field
- Log in with Username: admin, password: alphaadmin
- Select Station Main -> Main Settings, and enter the following parameters:
- Connect the IP substation and the AlphaCom XE (Eth1) to the same network switch
Configure the AlphaCom XE
- In AlphaPro go to Users & Stations, and select physical number 39; 139 Station 39
- Use the section on the right and change the configuration as follows:
Call Button
- In AlphaPro, Users & Stations, select physical port 39. Then press the button DAK, and configure as follows:
- Send the changes to the AlphaCom XE
Troubleshooting
- If the IP station does not register, check the following:
- In AlphaWeb, System Configuration -> Filters, verify that port for IP Stations and VoIP Audio is enabled
- In AlphaWeb, System Configuration -> Licenses, verify that there are licenses installed for the IP stations