Function required

A selection of intercom stations should, by dialing a number on the keypad, or by pressing a DAK key, be able to pulse a relay for 5 seconds.

Solution

The stations dial an Event Trigger number (feature 85), say number 9533, to pulse the RCO 3 for 5 seconds.

First, assign the stations to UDP group 1.

Second, in AlphaPro, go to Exchange and System -> Events, press Insert and create the following event:

Application20.png


Action commands:

RCO 3 ON 50