== Dimensions == | == Dimensions == | ||
=== VR3G-1=== | |||
*Dimensions (HxWxD): 160x114x60mm | *Dimensions (HxWxD): 160x114x60mm | ||
*Dimensions after flush mount: 160x114x5mm | *Dimensions after flush mount: 160x114x5mm | ||
[[File:VR3G-1 Dimensions.png|left| | [[File:VR3G-1 Dimensions.png|left|600px|thumb|VR3G-1 Dimensions]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
=== VR3G-1P=== | |||
* Dimensions (HxWxD): 160x114x60mm | |||
* Dimensions after flush mount: 160x114x4mm | |||
[[File:VR3G-1P Dimensions.png|left|600px|thumb|VR3G-1P Dimensions]] | |||
<br style="clear:both;" /> | |||
*Return to [[Vandal Resistant intercom - VR3G-1]] | *Return to [[Vandal Resistant intercom - VR3G-1]] | ||
*Return to [[Vandal Resistant intercom - VR3G-1P]] | *Return to [[Vandal Resistant intercom - VR3G-1P]] | ||
Latest revision as of 14:43, 8 September 2023
Installation
VR3G-1 can be powered by PoE. This is done by connecting an Ethernet cable to the LAN port of the station and a PoE switch.
| If PoE is used, the station must be installed using a shielded Ethernet cable with grounding at the switch end |
If the switch does not support PoE, a 24VDC power supply can be connected to the stations Power Input.
Mounting
Mounting considerations
Check the specification of the product for the installation environment.
| To ensure the IP66 rating and that nothing can penetrate behind the edge of the intercom, it must be mounted on a surface that is completely planar. |
Flush mounting
When flush mounting vandal resistant station, use the 3 Gang Flush Mount back box.
- Ready one of the pre-punched holes in the backbox for power and network wiring.
- Have the necessary cables ready before starting the mounting procedure
- Insert and secure the 3 Gang Flush Mount back box into designated slot in the wall. Make sure that the box is squarely mounted and the front surface flush with the wall surface.
- Plug the Ethernet cable into LAN port on the station. If the switch does not support PoE, a 24VDC Power Supply can be connected to the stations Power Input.
- Mount the Vandal Resistant Station onto the back box with the 6-32 UNC X ¾ fasteners provided. Apply 1.5 Nm / 1.1 lb-ft torque.
Dimensions
VR3G-1
- Dimensions (HxWxD): 160x114x60mm
- Dimensions after flush mount: 160x114x5mm
VR3G-1P
- Dimensions (HxWxD): 160x114x60mm
- Dimensions after flush mount: 160x114x4mm
- Return to Vandal Resistant intercom - VR3G-1