By default an input is triggered by a closing contact (referred to as "NO - Normally Open"). The input can be configured as "NC - Normally Closed" instead. (Requires firmware 8.1.3.0 or later). | By default an input is triggered by a closing contact (referred to as "NO - Normally Open"). The input can be configured as "NC - Normally Closed" instead. (Requires firmware 8.1.3.0 or later). | ||
− | + | Enable [[Advanced Configuration Mode (SIP)|Advanced Configuration]] mode, and select '''SIP Configuration > I/O''' from the menu | |
[[File:SIP IO.PNG|thumb|left|700px]] | [[File:SIP IO.PNG|thumb|left|700px]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> |
Revision as of 10:03, 12 January 2024
The Turbine range of stations have configurable I/O's, i.e. you can choose if an I/O should be used as an Input or as an Output. By default all I/O's are set as Inputs.
- When configured to be an Input, the input actions are configured from Direct Access Key Settings.
- When configured to be an Output, the output operation is configured from Relay Settings.
By default an input is triggered by a closing contact (referred to as "NO - Normally Open"). The input can be configured as "NC - Normally Closed" instead. (Requires firmware 8.1.3.0 or later).
Enable Advanced Configuration mode, and select SIP Configuration > I/O from the menu
For each of the six I/O pins the options are
- Input (default)
- Input NC - Normally Closed
- Output
Use Inputs As Key Matrix
If there is a need for more than the 6 inputs available, it is possible to use the Use Inputs As Key Matrix and combine inputs as in a diode matrix, and in this way create more DAKs. By for example using 3 inputs it is possible to get 7 DAKs.
This is enabled in Advanced Configuration Mode and IO Settings:
The different options are:
- 2 Inputs (input 1-2, DAK 1-3)
Input 2 | Input 1 | DAK key triggered |
0 | 1 | DAK1 |
1 | 0 | DAK2 |
1 | 1 | DAK3 |
0 | 0 | Last DAK released |
- 3 Inputs (input 1-3, DAK 1-7):
Input 3 | Input 2 | Input 1 | DAK key triggered |
0 | 0 | 1 | DAK1 |
0 | 1 | 0 | DAK2 |
0 | 1 | 1 | DAK3 |
1 | 0 | 0 | DAK4 |
1 | 0 | 1 | DAK5 |
1 | 1 | 0 | DAK6 |
1 | 1 | 1 | DAK7 |
0 | 0 | 0 | Last DAK released |
- 4 Inputs (input 1-4, DAK 1-15):
Input 4 | Input 3 | Input 2 | Input 1 | DAK key triggered |
0 | 0 | 0 | 1 | DAK1 |
0 | 0 | 1 | 0 | DAK2 |
0 | 0 | 1 | 1 | DAK3 |
0 | 1 | 0 | 0 | DAK4 |
0 | 1 | 0 | 1 | DAK5 |
0 | 1 | 1 | 0 | DAK6 |
0 | 1 | 1 | 1 | DAK7 |
1 | 0 | 0 | 0 | DAK8 |
1 | 0 | 0 | 1 | DAK9 |
1 | 0 | 1 | 0 | DAK10 |
1 | 0 | 1 | 1 | DAK11 |
1 | 1 | 0 | 0 | DAK12 |
1 | 1 | 0 | 1 | DAK13 |
1 | 1 | 1 | 0 | DAK14 |
1 | 1 | 1 | 1 | DAK15 |
0 | 0 | 0 | 0 | Last DAK released |
The DAK actions are configured from Direct Access Key Settings.
The input matrix function require Turbine software 4.7 or later.