Difference between revisions of "VSF-Fortitude6 8.2 Release Notes"
From Zenitel Wiki
(→VSF-FORTITUDE6 8.2.3.0) |
(→VSF-FORTITUDE6 8.2.3.0) |
||
Line 18: | Line 18: | ||
<br> | <br> | ||
− | =VSF-FORTITUDE6 8.2.3. | + | =VSF-FORTITUDE6 8.2.3.2= |
==Fixed Issues== | ==Fixed Issues== | ||
=== MTN-4479 The relay output in the CRM-V2 was not working in ICX-AlphaCom Mode in version 8.2.3.0 and 8.2.3.1 === | === MTN-4479 The relay output in the CRM-V2 was not working in ICX-AlphaCom Mode in version 8.2.3.0 and 8.2.3.1 === | ||
Line 27: | Line 27: | ||
<br> | <br> | ||
− | |||
− | |||
=VSF-FORTITUDE6 8.2.3.0= | =VSF-FORTITUDE6 8.2.3.0= |
Revision as of 10:41, 3 July 2024
- Previous Release - VSF-Fortitude6 8.1 Release Notes
This document provides the release notes for VSF-Fortitude6 8.2 with incremental bug fix releases. The release notes for VSF-Fortitude6 8.2 describe new features, improvements and issues fixed after VSF-Fortitude6 8.1.3.2.
Contents
- 1 Release info
- 2 VSF-FORTITUDE6 8.2.3.2
- 3 VSF-FORTITUDE6 8.2.3.0
- 3.1 Improvements
- 3.2 Fixed Issues
- 3.2.1 MTN-4435 RTSP stream could stop in some cases
- 3.2.2 MTN-4394 Multicast paging working again on intercom devices
- 3.2.3 MTN-4362 Fixed wrong description in Sound Detection settings
- 3.2.4 MTN-4340 ONVIF backchannel could cut last second of audio
- 3.2.5 MTN-4329 Fixed an issue with wrong intervals for ONVIF events reports
- 3.2.6 MTN-4320 Weak cipher suites no longer supported on devices
- 3.2.7 MTN-4246 Fixed an issue with input status on CRM-V2 that was lost after ICX-AlphaCom restart
- 3.2.8 MTN-4228 Turbine devices could not be used with Bosch VMS
Release info
Name: VSF-Fortitude6
Description: VSF-Fortitude6 is a firmware for Zenitel devices based on the IMX6 processor.
The firmware is delivered in two different files:
- vsff6-8.2.3.x - Used for standard in-field upgrades
- vsff6-prod-8.2.3.x - Used in production- and recovery upgrades.
Version: 8.2.3.2
Date: 03.07.2024
Status: General Availability
VSF-FORTITUDE6 8.2.3.2
Fixed Issues
MTN-4479 The relay output in the CRM-V2 was not working in ICX-AlphaCom Mode in version 8.2.3.0 and 8.2.3.1
This is now fixed.
MTN-4471 The IP telephony feature in IC-Edge was not working in version 8.2.3.0 and 8.2.3.1
This is now fixed.
VSF-FORTITUDE6 8.2.3.0
Improvements
DS-899 SIP/SDP support for dynamic payload for codec L16x48 (HD-Audio)
Now supporting SIP media attribute L16/48000 with dynamic payload type in range 96..127. Note! The device needs to be configured in “HD-Audio” mode and voice processing (AEC and NC) is not supported.
Fixed Issues
MTN-4435 RTSP stream could stop in some cases
In case of audio issues, RTSP stream would terminate. Now the stream will continue with a moment of silence instead.
MTN-4394 Multicast paging working again on intercom devices
Multicast paging was not working on intercom devices when configuring from the webpage. This is now fixed.
MTN-4362 Fixed wrong description in Sound Detection settings
The description of “Minimum time before reactivation” is corrected to “Choose how long to wait before enabling VAD after triggering the DAK key”
MTN-4340 ONVIF backchannel could cut last second of audio
In some cases backchannel could cut around last second of audio when using push to talk or pre-recorded messages that terminate backchannel session.
This does not happen anymore if client sends TEARDOWN command correctly.
MTN-4329 Fixed an issue with wrong intervals for ONVIF events reports
Fixed an issue with wrong parsing of some PullMessages parameters. In some VMSs, PullMessages parameters Timeout and MessageLimit were not parsed correctly on VS-IS8.0.3.2 and wrong values were used.
MTN-4320 Weak cipher suites no longer supported on devices
Removed the AES128-SHA AES128-SHA256:ECDHE-RSA-AES128-SHA:ECDHE-RSA-AES256-SHA:CAMELLIA128-SHA:CAMELLIA256-SHA ciphers reported by security scanner
MTN-4246 Fixed an issue with input status on CRM-V2 that was lost after ICX-AlphaCom restart
After ICX-AlphaCom was restarted the input status of the CRM-V2 was lost. This is now fixed.
MTN-4228 Turbine devices could not be used with Bosch VMS
There was a problem on Zenitel ONVIF devices that caused software to crash and device to reboot which made Bosch VMS unable to connect to the device.