Actions

Difference between revisions of "Modify ASVP alarm message repetitions"

From Zenitel Wiki

(Using the Event Handler)
(Using the Event Handler)
Line 50: Line 50:
 
Explanation of the parameters in the command $SNV '''''Q1''''' W2 W2 '''''W1''''' W3:
 
Explanation of the parameters in the command $SNV '''''Q1''''' W2 W2 '''''W1''''' W3:
  
* Q1 = Number of repetitions, here 1
+
* '''''Q1''''' = Number of repetitions, here 1
 
* W2 = NVRAM table 2, ex_mi…  
 
* W2 = NVRAM table 2, ex_mi…  
 
* W2 = NVRAM subtable 2,.ex_mi_announce_tab[81]
 
* W2 = NVRAM subtable 2,.ex_mi_announce_tab[81]
* W1 = Message number 1 (*)
+
* '''''W1''''' = Message number 1 (*)
 
* W3 = NVRAM line 3, line 3: ….tab[1].repeat
 
* W3 = NVRAM line 3, line 3: ….tab[1].repeat
  

Revision as of 13:59, 1 September 2017

AlphaCom icon 300px.png

By default the ASVP alarm messages are repeated endlessly, but for some applications it is required that the message is played once or a few times and then stop. For each alarm message there is a parameter that controls the number of repetitions. As this parameter is not available from AlphaPro, it has to be changed directly in the AMC memory, using the nvram editor in the TST console or the $SNV command from the Event Handler.

NOTE: Before continuing it is highly recommended to do a backup of AMC memory to Flash. Dial 7820+M from a SuperUser station.

Procedure

.ex_mi.announce_tab[n].repeat       

where n = message number.

Set number of repetitions of the alarm message (1 to 255, 255 is endless)


Example

Using the TST Console

Changing the parameter for alarm message 1 (Directory number 8191) to play once, then stop.

Start the TST Console, then:

Type: Explanation
nvram <Enter><Enter> Start the nvram editor from the TST console
2 <Enter> Enter line 2: .ex_mi…
2 <Enter> Enter line 2: .ex_mi_announce_tab[81]
1 <Enter> Select alarm message number 1 (*)
3 <Enter> Enter line 3: ….tab[1].repeat = 255
1 <Enter> Set number of repetitions of alarm message, here 1
Q <Enter> Exit NVRAM table, and save changes

(*) Use message number 2 - 9 for the messages 8192 - 8199.

Using the Event Handler

Changing the parameter for alarm message 1 (Directory number 8191) to play once, then stop:

Using event 27 and the SNV command to modify the nvram settings at exchange start-up


The event type 27, subvent 65, is triggered every time the exchange starts up.

Explanation of the parameters in the command $SNV Q1 W2 W2 W1 W3:

  • Q1 = Number of repetitions, here 1
  • W2 = NVRAM table 2, ex_mi…
  • W2 = NVRAM subtable 2,.ex_mi_announce_tab[81]
  • W1 = Message number 1 (*)
  • W3 = NVRAM line 3, line 3: ….tab[1].repeat

(*) Use message number 2 - 9 for the messages 8192 - 8199.