|1||[[NET_OBJ_REF]]<br\>{[[ECL_STATION]]}||colspan="3"|Station. Null value not allowed.<br\>.
 
|-
 
|-
'''|colspan="5"|$DSPL  L101  U18  0311  ‘Line 1 text’<br\>  
+
|colspan="5"|$DSPL  L101  U18  0311  ‘Line 1 text’<br\>  
 
$DSPL  L101  U18  0312  ‘Line 2 text’<br\>
 
$DSPL  L101  U18  0312  ‘Line 2 text’<br\>
 
$DSPL  L104 U23  0313 14 "Line 3 text on CRM  "<br\>
 
$DSPL  L104 U23  0313 14 "Line 3 text on CRM  "<br\>
Line 14: Line 14:
 
Dual Display (from AMC 08.28 / 09.01):<br\>
 
Dual Display (from AMC 08.28 / 09.01):<br\>
 
1. $DSPL  L104 U11  33011302 ‘DAK line’<br\>   
 
1. $DSPL  L104 U11  33011302 ‘DAK line’<br\>   
2. $DSPL  L104 U3    500400 ‘’<br\>''' 
+
2. $DSPL  L104 U3    500400 ‘’<br\>  
 
|-
 
|-
 
|colspan="5"|Send text and control characters to a station in a station dependent low level format.<br\>
 
|colspan="5"|Send text and control characters to a station in a station dependent low level format.<br\>
Line 24: Line 24:
 
Example 2. Select (show) DAK page 04 on DualDisplay station with no arrow indication (last 00. Arrow down is visible if (last) number is 2 or more. Arrow up is visible if number is larger than the page number).
 
Example 2. Select (show) DAK page 04 on DualDisplay station with no arrow indication (last 00. Arrow down is visible if (last) number is 2 or more. Arrow up is visible if number is larger than the page number).
 
|-
 
|-
|1||[[NET_OBJ_REF]]<br\>{[[ECL_STATION]]} ||colspan="3"|Station displaying text.<br\>AlphaNet: B station in B exchange.
+
|1||[[NET_OBJ_REF]]<br\>{[[ECL_STATION]]} ||colspan="3"|Station displaying text.<br\>[[AlphaNet]]: B station in B exchange.
 
|-
 
|-
 
|2||[[UINT1]]||colspan="3"|Length of text
 
|2||[[UINT1]]||colspan="3"|Length of text

Revision as of 11:23, 12 June 2007

DISPLAY_TEXT 0x005A 90 AMC 06.00
1 NET_OBJ_REF<br\>{ECL_STATION} Station. Null value not allowed.<br\>.
$DSPL L101 U18 0311 ‘Line 1 text’<br\>

$DSPL L101 U18 0312 ‘Line 2 text’<br\> $DSPL L104 U23 0313 14 "Line 3 text on CRM "<br\> $DSPL L104 U23 0313 54 "Line 4 text on CRM "<br\> Dual Display (from AMC 08.28 / 09.01):<br\> 1. $DSPL L104 U11 33011302 ‘DAK line’<br\> 2. $DSPL L104 U3 500400 ‘’<br\>

Send text and control characters to a station in a station dependent low level format.<br\>

The character set is ISO 8859 (for characters from 20 hex an above). The control characters used conforms to the TouchLine display format code for control of the display.<br\> AlphaNet: Message from remote exchange in order to display the enclosed text in a local station.<br\><br\> Note that the exchange updates the display frequently, and external control of the display will work only in special situations.<br\><br\> Dual Display:<br\> Example 1. Update text on DAK display line 02. legal values 01->64 (1-100 decimal)<br\> Example 2. Select (show) DAK page 04 on DualDisplay station with no arrow indication (last 00. Arrow down is visible if (last) number is 2 or more. Arrow up is visible if number is larger than the page number).

1 NET_OBJ_REF<br\>{ECL_STATION} Station displaying text.<br\>AlphaNet: B station in B exchange.
2 UINT1 Length of text
3 Array of UINT1 Text characters.