A Zenitel IP Speaker (ZIPS) may have to be reset to its original factory default settings if, for instance, the password to the station web interface is forgotten. The defaults can either be set to Activated DHCP or Static IP. | A Zenitel IP Speaker (ZIPS) may have to be reset to its original factory default settings if, for instance, the password to the station web interface is forgotten. The defaults can either be set to Activated DHCP or Static IP. | ||
Factory default settings can be [[Restore Factory Defaults - From the device web interface|restored from the web interface]], or by a hardware reset as explained below. | |||
__NOTOC__ | __NOTOC__ | ||
Revision as of 10:53, 10 January 2025
A Zenitel IP Speaker (ZIPS) may have to be reset to its original factory default settings if, for instance, the password to the station web interface is forgotten. The defaults can either be set to Activated DHCP or Static IP.
Factory default settings can be restored from the web interface, or by a hardware reset as explained below.
Preparation
- Connect a push button between the IO connector (pin 1) and Ground (pin 11)
Reset to Factory Default Settings with Activated DHCP
To reset:
- While pressing the button, power up the device by connecting to a PoE switch
- Hold the button until the device audio starts counting, and release the button on count 1
- Press and hold the button on count 5 and release on count 0
- If there is no 0 count, the procedure has failed and you have to start again
- Press the button, and the device will speak its IP address
Factory default values
- Device IP address: Determined by DHCP server. If no DHCP server is available, it gets a random 169.254.x.x address.
- Username: admin
- Password: alphaadmin
Reset to Factory Default Settings with Static IP
To reset:
- While pressing the button, power up the device by connecting to a PoE switch
- Hold the button until the device audio starts counting, and release the button on count 1
- Press and hold the button on count 3 and release on count 0
- If there is no 0 count, the procedure has failed and you have to start again
- Press the button, and the device will speak its IP address
Factory default values
- Device IP address: 169.254.1.100
- Username: admin
- Password: alphaadmin