Upgrade AlphaCom XE1 to ICX-510: Difference between revisions
From Zenitel Wiki
| Line 19: | Line 19: | ||
==ICX-AlphaCom == | ==ICX-AlphaCom == | ||
* Upgrade the ICX-AlphaCom to the latest version | * Upgrade the ICX-AlphaCom to the latest software version | ||
* Enter the [[ICX_Web|ICX-510 web-interface]] and configure according to the screenshots made from the AlphaCom XE1 | * Enter the [[ICX_Web|ICX-510 web-interface]] and configure according to the screenshots made from the AlphaCom XE1 | ||
{{Note|Upload audio messages if any}} | {{Note|Upload audio messages if any}} | ||
Revision as of 13:49, 3 April 2025
This article describes best practice to replace an AlphaCom XE1 with an ICX-510 running AlphaCom software.
AlphaCom XE1
- Check AlphaCom XE1 software version. If the version is below 12.x.x.x the board should be upgraded to latest version. upgrade procedure.
- Make screenshots of AlphaWeb System Configuration pages:
- Interfaces
- Filters
- Routing
Optional:
- Time and Date
- Logging
- Messaging
- Use latest AlphaPro version and perform a Get All to backup the configuration.
ICX-AlphaCom
- Upgrade the ICX-AlphaCom to the latest software version
- Enter the ICX-510 web-interface and configure according to the screenshots made from the AlphaCom XE1
- Upload license file
- Use AlphaPro and perform Send All