Actions

Upgrade AlphaCom XE1 to ICX-510: Difference between revisions

From Zenitel Wiki

No edit summary
No edit summary
Line 16: Line 16:
# Messaging
# Messaging
  {{Note|If there are audio messages uploaded to the server, download and store these on your laptop.}}  
  {{Note|If there are audio messages uploaded to the server, download and store these on your laptop.}}  
* Use latest AlphaPro version and perform a Get All to backup the configuration.
* Use latest AlphaPro version and perform a '''Get All''' to backup the configuration.


==ICX-AlphaCom ==
==ICX-AlphaCom ==

Revision as of 13:55, 3 April 2025

AI.png

This article describes best practice to replace an AlphaCom XE1 with an ICX-510 running AlphaCom software.

UpgradeXE1toICX.png

AlphaCom XE1

  • Check the AlphaCom XE1 software version. If the version is 11.x.x.x or older, the server should be upgraded to latest version, see upgrade procedure.
  • Make screenshots of AlphaWeb System Configuration pages:
  1. Interfaces
  2. Filters
  3. Routing


Optional:

  1. Time and Date
  2. Logging
  3. Messaging
Note icon If there are audio messages uploaded to the server, download and store these on your laptop.


  • Use latest AlphaPro version and perform a Get All to backup the configuration.

ICX-AlphaCom

  • Upgrade the ICX-AlphaCom to the latest software version
  • Log in to the ICX-510 web-interface and configure according to the screenshots made of the AlphaCom XE1
  • Upload audio messages if any
  • Upload license file
  • From AlphaPro connect to the ICX-510 and restore the configuration by doing a Send All
MediaWiki spam blocked by CleanTalk.