Actions

Difference between revisions of "ALARM MSG"

From Zenitel Wiki

Line 16: Line 16:
 
-Null value or directory number for "alarm message off" disconnects any active message(s).
 
-Null value or directory number for "alarm message off" disconnects any active message(s).
 
|-
 
|-
|align=center|3||[[NET_OBJ_REF]]||colspan="3"|Extra parameter (time/date/phone number) in [[DIGIT_STRING]] format or Null if no parameter.
+
 
|-
 
|align=center|4||[[TEXT16]]||colspan="3"|Absence Message as Text. All spaces if Present (no message).
 
|-
 
 
|colspan="2"|Response:||colspan="3"|[[ALARM_MSG_ACK]]
 
|colspan="2"|Response:||colspan="3"|[[ALARM_MSG_ACK]]
 
|-
 
|-

Revision as of 06:40, 12 December 2011

ALARM_MSG 0x0007 7 AMC 05.00
$ALRM L101 N!1 <br\> $ALRM L890 N!1 <br\> $ALRM L890 L8191
Set up (or disconnect) an ASVP Alarm message to a single station or a predefined group of stations.
1 NET_OBJ_REF <br\>{ECL_STATION,<br\>ECL_ST_GROUP} Station or group.
2 NET_OBJ_REF<br\>{ECL_ANNOUNCEMENT} Which alarm message.<br\>

-Null value or directory number for "alarm message off" disconnects any active message(s).

Response: ALARM_MSG_ACK

Back to AlphaNet message list