Line 12: Line 12:
 
# Release the button '''after exactly 2 flashes''' of the LED.
 
# Release the button '''after exactly 2 flashes''' of the LED.
 
# Let the LED flash for '''exactly 2 more times''' (Static IP) or '''exactly 4 more times''' (DHCP), then press the button again.
 
# Let the LED flash for '''exactly 2 more times''' (Static IP) or '''exactly 4 more times''' (DHCP), then press the button again.
# Keep the button pressed until the LED '''flashes fast 2 time'''s (Static IP) or '''flashes fast 4 times''' (DHCP) indicating a successful reset.
+
# Keep the button pressed until the LED '''flashes fast 2 times''' (Static IP) or '''flashes fast 4 times''' (DHCP) indicating a successful reset.
 
# Release the button and the station will restart with the factory default settings.
 
# Release the button and the station will restart with the factory default settings.
 +
 +
  
 
Factory default values:
 
Factory default values:

Revision as of 13:28, 17 March 2017

APS.png

This procedure is applicable for:

The unit can be set to use either Static IP or DHCP. On the rear side of the PCB there is a red status LED. Pay attention to this LED during the restore procedure:

Connect a push button between pins 1 and 4
  1. Connect a push button (KEY1) between pin 1 and 4 on the P4 connector.
  2. While pressing the button, power up the station kit and keep the button pressed.
  3. Release the button after exactly 2 flashes of the LED.
  4. Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
  5. Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
  6. Release the button and the station will restart with the factory default settings.


Factory default values:

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100 or DHCP
  • Username: admin
  • Password: alphaadmin