Difference between revisions of "AlphaVision - How to get started"
From Zenitel Wiki
Line 1: | Line 1: | ||
[[Image:AlphaVision - example.png|thumb|AlphaVision - Example configuration]] | [[Image:AlphaVision - example.png|thumb|AlphaVision - Example configuration]] | ||
This article gives step-by-step instructions how to get started with [[AlphaVision]]. | This article gives step-by-step instructions how to get started with [[AlphaVision]]. | ||
− | + | <br style="clear:both;" /> | |
=== AlphaWeb === | === AlphaWeb === | ||
* In System Configuration -> Filters, enable TCP port 55010 on the ethernet port used for AlphaVision. | * In System Configuration -> Filters, enable TCP port 55010 on the ethernet port used for AlphaVision. |
Revision as of 17:25, 26 November 2008
This article gives step-by-step instructions how to get started with AlphaVision.
AlphaWeb
- In System Configuration -> Filters, enable TCP port 55010 on the ethernet port used for AlphaVision.
AlphaPro
- In Exchange & System -> Serial ports, activate a communication port to be used for AlphaVision. Select one of the 7 ACDP ports, and set the following parameters:
- Port Type: TCP/IP Server
- Link Type: Stentofon MultiDrop Master - Reserved
- Broadcast: Enabled
- Destination: AlphaVision (optional)
- Port: 55010
- Keep Alive: Enabled
- In Exchange & System -> Devices, scroll down to device 64 and set:
- Device type: Operator (passive)
- Data (ACDP link): select the link which was configured in the Serial Ports window
AlphaVision
- Download and install AlphaVision on a PC. Latest software version is available on the download site.
- Start the 'AVCMSetup' program (XP: Start-> All Programs -> AlphaVision: AVCMSetup). Set:
- Communiation Type: IP
- AC E IP address: The IP address of the AlphaCom
- Leave the other parameters as is. Press OK to close the window.
- Start the AlphaVision program. Username = service, password = service (Supervisor login)
- Select the 'System tree' tab. AlphaVision will automatically detect stations as they are being used, and they will show up in the System Tree. However, by dialling the code 7885 (Tone Test) from a SuperUser, all stations will automatically be detected one by one.
- Assign an 'Operator station' to AlphaVision by selecting Configuration -> Options -> Systems tab. By default station 102 in node 1 is set as operator station if found, and no other station is defined.