!style="background:#ffdead;" |AMC 11.00 | !style="background:#ffdead;" |AMC 11.00 | ||
|- | |- | ||
− | |colspan="3"|'''$GM L84 L8181''' <br> '''$GM L85 L8193 U1 U0 U0''' <br>'''$GM L9001 L8182 U10 U0 U0''' <BR> '''$GM NG1 N!4 U3 U2 U0''' <br> || colspan="2"|No repetition and use group gong and priority <br | + | |colspan="3"|'''$GM L84 L8181''' <br> '''$GM L85 L8193 U1 U0 U0''' <br>'''$GM L9001 L8182 U10 U0 U0''' <BR> '''$GM NG1 N!4 U3 U2 U0''' <br> || colspan="2"|No repetition and use group gong and priority <br /> No repetitions and no gong <br /> 10 repetitions and no gong <br> To group 1 (84), activate alarm message 4 (8194), 3 repetitions, use gong type 2 (dong-ding) <br> |
|- | |- | ||
|colspan="5"|GROUP_MSG sets up a local or global group call with source a SVP message. To stop message playback use [[GROUP_MSG_STOP]] | |colspan="5"|GROUP_MSG sets up a local or global group call with source a SVP message. To stop message playback use [[GROUP_MSG_STOP]] | ||
|- | |- | ||
− | |align=center|1||[[NET_OBJ_REF]] <br | + | |align=center|1||[[NET_OBJ_REF]] <br />{[[ECL_ST_GROUP#NET_OBJ_REF:_Entity_Classes|ECL_LOCAL_GROUP]], <BR\> [[ECL_ST_GROUP#NET_OBJ_REF:_Entity_Classes|ECL_GLOBAL_GROUP]]}||colspan="3"| Destination local or global group |
|- | |- | ||
− | |align=center|2||[[NET_OBJ_REF]]<br | + | |align=center|2||[[NET_OBJ_REF]]<br />{[[ECL_ANNOUNCEMENT]], <br> [[ECL_STATION]], <BR\> [[ECL_USER]]}||colspan="3"| Initiator station or Announcement message for playback in group.<br> '''Note''': The N!x parameter works for announcement message 1-9 only (N!1 - N!9). Use directory numbers to address more messages. |
|- | |- | ||
|align=center|3||[[UINT1]]<BR\>(optional)||colspan="3"|SVP Message repetitions 0-255. 0 or unspecified means 1 repetition. 255 means repeat indefinitely (use [[GROUP_MSG_STOP]] to stop). (If PA bitmap defined, this parameter is overrun by the PA bitmap def) | |align=center|3||[[UINT1]]<BR\>(optional)||colspan="3"|SVP Message repetitions 0-255. 0 or unspecified means 1 repetition. 255 means repeat indefinitely (use [[GROUP_MSG_STOP]] to stop). (If PA bitmap defined, this parameter is overrun by the PA bitmap def) | ||
Line 18: | Line 18: | ||
|align=center|4||[[UINT1]]<BR\>(optional)||colspan="3"| Gong type. 0 = no gong. 255 or unspecified = use gong type of group. | |align=center|4||[[UINT1]]<BR\>(optional)||colspan="3"| Gong type. 0 = no gong. 255 or unspecified = use gong type of group. | ||
|- | |- | ||
− | |align=center|5||[[UINT1]]<br | + | |align=center|5||[[UINT1]]<br />(optional)||colspan="3"| Group call priority, default 0 = use priority of group call. <br> 1 = Low, 2 = Medium, 3 = High, 4 = Alarm. "Alarm" priority will activate [[Volume and handset override|Volume and Handset Override]] |
|- | |- | ||
|colspan="2"|Response||colspan="3"| none | |colspan="2"|Response||colspan="3"| none |
Revision as of 10:41, 8 March 2016
GM (GROUP_MSG) | 0x00A6 | 166 | AMC 11.00 | |
---|---|---|---|---|
$GM L84 L8181 $GM L85 L8193 U1 U0 U0 $GM L9001 L8182 U10 U0 U0 $GM NG1 N!4 U3 U2 U0 |
No repetition and use group gong and priority No repetitions and no gong 10 repetitions and no gong To group 1 (84), activate alarm message 4 (8194), 3 repetitions, use gong type 2 (dong-ding) | |||
GROUP_MSG sets up a local or global group call with source a SVP message. To stop message playback use GROUP_MSG_STOP | ||||
1 | NET_OBJ_REF {ECL_LOCAL_GROUP, <BR\> ECL_GLOBAL_GROUP} |
Destination local or global group | ||
2 | NET_OBJ_REF {ECL_ANNOUNCEMENT, ECL_STATION, <BR\> ECL_USER} |
Initiator station or Announcement message for playback in group. Note: The N!x parameter works for announcement message 1-9 only (N!1 - N!9). Use directory numbers to address more messages. | ||
3 | UINT1<BR\>(optional) | SVP Message repetitions 0-255. 0 or unspecified means 1 repetition. 255 means repeat indefinitely (use GROUP_MSG_STOP to stop). (If PA bitmap defined, this parameter is overrun by the PA bitmap def) | ||
4 | UINT1<BR\>(optional) | Gong type. 0 = no gong. 255 or unspecified = use gong type of group. | ||
5 | UINT1 (optional) |
Group call priority, default 0 = use priority of group call. 1 = Low, 2 = Medium, 3 = High, 4 = Alarm. "Alarm" priority will activate Volume and Handset Override | ||
Response | none |