Actions

IP Video Door Station - 1401110200

From Zenitel Wiki

Revision as of 12:59, 5 November 2014 by Roarl (talk) (CP-Cam Factory Reset)
IP Video Station, item 1401110200

Camera Type: Axis

The STENTOFON Vandal Resistant IP Video Station (item 1401110200) is tough, durable and resilient, and designed for use in the harshest of environments. The station is typically used as a communication, information or emergency point and connects directly to the IP network making it easy to deploy – anywhere and at any distance. Designed for CCoIP® the station offers a set of critical communication features such as integrated firewall, group call, call priority and over-ride, to name just a few. This enables you to deliver instant, efficient and secure voice, video and data services in an IP environment.

Installation

See article: IP Station Installationxx

Station Board Connectors and LED Indications

See article: IP Station Board Connections and Indications

IP Station Configuration

See article: IP Station Configuration

Reset to factory settings

See article: IP Station Restore Factory Defaults

Software Upgrade

See article: IP Station Software upgrade

Dimensions

See article: IP Stations Dimensions and Mounting Instructions

Camera configuration

Connect to the camera using a webbrowser on default IP address 169.254.1.101.

In the menu that appears, click System Settings, and you will be asked to login:

Username: admin
Password: 1234

Set to factory default:

Axis Factory Reset

To restore the factory settings, proceed as follows:

1. Disconnect the camera from the power supply and ethernet.
2. Remove the four screws securing the rear cover and remove it.
3. Keep the Control button pressed while you restore the power supply.
4. Hold down the button for about 15 seconds until the status LED is yellow flashing.
5. Release the Control Button. The process is complete when the status LEDs light up green.
Axis.PNG


If no DHCP server is active on your network the new default IP is 192.168.0.90.
The new default user is root with password pass

Setup with STENTOFON Video Display Station

To configure the STENTOFON Video Display Station please see: IP Desktop Station with Video Display - 1408001635

This chapter describes the steps for configuring the CP-Cam:

From the Main Menu select System Settings > Network

1. Under section IP-SETUP, set IP-SETUP Type to Manual
IP-VideoDoorStation1.png


2. Enter a static IP adresss, Netmask, Gateway and DNS
3. Under section System, set Authentication required for Picture/Video to No
IP-VideoDoorStation2.png


4. Click Save Changes at the bottom of the page



From the Main Menu select System Settings > Camera

1. Under section Settings, set Mode to Custom
2. Set Res X to 320
3. Set Res Y to 240
IP-VideoDoorStation3.png


4. Under section Settings, set Frames per Second (Sensor) to 15