This procedure is applicable for the stations:

This procedure is also applicable for the kits. This requires that a push button is connected between pin 1 and pin 4 on connector P4.

Kits require a push button to be connected between pins 1 and 4

The unit can be set to use either Static IP or DHCP. Pay attention to the call LED during the restore procedure:

  1. While pressing the call button, power up the station and keep the button pressed.
  2. Release the button after exactly 2 flashes of the LED.
  3. Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
  4. Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
  5. Release the button and the station will restart with the factory default settings.

Factory default values:

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100 or DHCP
  • Username: admin
  • Password: alphaadmin

An IP Station may have to be reset to its original factory default settings if, for instance, the password to the webserver is forgotten.

The defaults can be either be set to Static IP or Activated DHCP (when there are many new IP Substations in an installation).


Load Defaults without Display - 1.PNG


Load Defaults without Display - 2.PNG



* Software 01.06 and earlier: ADMIN/alphacom)