VSF-Fortitude6 6.1 Release Notes
From Zenitel Wiki
Contents
- 1 Release info
- 2 VSF-FORTITUDE6 6.1.3.0
- 2.1 New Features
- 2.2 Improvements
- 2.2.1 MTN-3172 Setting custom hostname now survives station reboot
- 2.2.2 MTN-3169 Reduced handset gain
- 2.2.3 MTN-3165 TCIV+ volume not properly applied after start-up/reboot
- 2.2.4 MTN-3125 Station reboots when scanning port 5060 or 5061
- 2.2.5 MTN-3117 Configuration of "Read IP" address now available for device from an Edge Controller.
- 2.2.6 MTN-3115 Status LED not working in all states.
- 2.2.7 MTN-3114 Force loudspeaker ringing option has changed default value
- 2.2.8 MTN-3113 AGC not available from Edge Controller for IP Desk Master V2
- 2.2.9 MTN-3112 Ringlists can now be saved if device is an Edge Controller
- 2.2.10 MTN-1466 Cannot save firewall settings for same port with different protocols
- 2.3 Issues fixed
- 2.4 Known issues
Release info
This document provides the release notes for VSF-Fortitude6 6.1 with incremental bug fix releases. The release notes for VSF-Fortitude6 6.1 describe new features, improvements and issues fixed after VSF-Fortitude6 6.0.
Name: VSF-Fortitude6
Description: VSF-Fortitude6 is a firmware for IP Desk Master -V2, IP Flush Master -V2 and IP OR Master -V2
The firmware is delivered in two different files:
- vsff6-6.1.3.x - Used for standard in-field upgrades
- vsff6-prod-6.1.3.x - Used in production- and recovery upgrades.
Version: 6.1.3.0
Date: 07.04.2021
Status: General Availability
Compatibility: IP Desk Master V2 and IP Flush Master V2 and IP-OR Master are compatible with Edge, SIP, ICX and AlphaCom systems.
VSF-FORTITUDE6 6.1.3.0
New Features
TYR-11 Support for external speaker
Option to connect an external speaker to IP Flush Master V2 and IP CROR Stations. The external speaker can be activated in Audio settings on the web.
MTN-3144 Third button option for hold state.
Added third button option under Direct Access Keys for managing calls that are put on hold. This option is available in SIP and Edge.
Improvements
MTN-3172 Setting custom hostname now survives station reboot
If hostname was modified, it would revert back to the default hostname after reboot. This is now fixed.
MTN-3169 Reduced handset gain
The handset gain of IP Desk Master V2 has been reduced with 6 dB to make handset gain at level with IP Desk Master handset (previous hardware version).
MTN-3165 TCIV+ volume not properly applied after start-up/reboot
At start-up the main speaker volume was set to a low gain level (close config level 3) when a higher gain was configured. Any later gain change would set correct speaker gain. This is fixed, the set speaker gain will be applied after start-up as well.
MTN-3125 Station reboots when scanning port 5060 or 5061
Scanning SIP TCP port 5060 or SIPS TCP port 5061 would crash and reboot the TCIV+. This issue has been fixed.
MTN-3117 Configuration of "Read IP" address now available for device from an Edge Controller.
MTN-3115 Status LED not working in all states.
This has now been fixed.
MTN-3114 Force loudspeaker ringing option has changed default value
The option "Force loudspeaker ringing" option has changed default value from on to off. When "force loudspeaker ringing" is on, the IP Desk Master V2 will ring in speaker and handset when doing a private call.
MTN-3113 AGC not available from Edge Controller for IP Desk Master V2
This is now fixed.
MTN-3112 Ringlists can now be saved if device is an Edge Controller
If device was an Edge Controller, the ringlist could not be saved. This has now been fixed.
Note, the ringlist worked fine if a different device was used as Edge Controller e.g. TCIS.
MTN-1466 Cannot save firewall settings for same port with different protocols
It was not possible to save firewall settings if rules with the same port number but different protocols (for example port 5060 which has rules for tcp and udp) were edited. This is now fixed.
Issues fixed
Known issues