IMT - Release Notes
From Zenitel Wiki
Contents
- 1 Release info
- 2 Version 3.2.3.0
- 3 Version 3.1.3.2
- 4 Version 3.1.3.0
- 5 Version 2.2
- 6 Version 2.1
- 6.1 Improvements
- 6.2 Issues fixed
- 6.2.1 MTN-3295 Full version import and upgrade using VS-IMT fixed
- 6.2.2 MTN-3283 Support for ICX AlphaCom
- 6.2.3 MTN-3110 Does not show warning for TCIV+ as Edge Controller
- 6.2.4 MTN-3106 Proper handling for leading zeroes in directory number
- 6.2.5 MTN-3056 VS-IMT available for Windows usernames with special characters
- 6.3 Known Issues
- 7 Version 2.0
- 8 Version 1.5
- 9 Version 1.4
- 9.1 New Features
- 9.1.1 VSIS-434 Turbine address book CSV download and upload
- 9.1.2 VSIS-680 New Profile Management
- 9.1.3 VSIS-681 Configuration tools redesign
- 9.1.4 VSIS-746 Support for VS-IS 4.7 firmware settings
- 9.1.5 VSIS-1079 Support for Exigo/PA firmware
- 9.1.6 VSIS-1148 Project export includes all station files
- 9.1.7 VSIS-1174 Mass configuration of 802.1x settings from VS-IMT
- 9.1.8 VSIS-1175 Mass configuration of INCA VLAN settings from VS-IMT
- 9.1.9 VSIS-1180 Upgrade crash rescue mode
- 9.2 Bugfixes and improvements ver. 1.4.3.5
- 9.2.1 SNOW-1111 ENA-2060/2100 support in VS-IMT
- 9.2.2 SNOW-1033 Show warning for non-supported target firmware upgrade version
- 9.2.3 SNOW-1001 Support for syslog configuration
- 9.2.4 SNOW-983 Support for new DAK call actions
- 9.2.5 SNOW-422 VS-IMT upgrade: Automatic selection of imported image
- 9.2.6 SNOW-1264 Support for VS-IS 4.11 firmware settings
- 9.3 Bugfixes and improvements ver. 1.4.3.4
- 9.3.1 SNOW-918 TCIV-5 support in VS-IMT
- 9.3.2 MTN-1872 Export VS-IMT logs from all IP stations
- 9.3.3 SNOW-581 IMT Changes: New devices added
- 9.3.4 SNOW-422 VS-IMT upgrade: Automatic selection of imported image
- 9.3.5 SNOW-582 IP-LCM support in VS-IMT
- 9.3.6 SNOW-473 TKIS-3 and TKIE-4 support in VS-IMT
- 9.4 Bugfixes and improvements ver. 1.4.3.3 (GA)
- 9.4.1 VSIS-1231 VAD Minimum amplitude (dBA) can't be set for INCA stations in VS-IMT
- 9.4.2 VSIS-1147 VS-IMT Wizard sets static IP address without Gateway
- 9.4.3 SNOW-385 VS-IMT - Warning label for TCIV as Pulse server
- 9.4.4 SNOW-239 Enable all DAK actions for all Turbine stations in VS-IMT
- 9.4.5 MTN-1748 VS-IMT firmware image import should have progress bar
- 9.4.6 MTN-1421 Noise Reduction level should not be configurable from IMT in AlphaCom mode
- 9.4.7 MTN-1012 VS-IMT not showing licenses if INCA is Pulse server
- 9.5 Bugfixes and improvements ver. 1.4.3.2 (GA)
- 9.6 Bugfixes and improvements ver. 1.4.3.1 (GA)
- 9.7 Bugfixes and improvements ver. 1.4.3.0 (GA)
- 9.8 Bugfixes and improvements ver. 1.4.2.4 (LA)
- 9.8.1 VSIS-593 Switching Turbine station between DHCP and Static IP fails in some cases
- 9.8.2 VSIS-833 Wizard should ask to apply changes to Pulse server directory
- 9.8.3 VSIS-881 VS-IMT sets headset on Turbine Compact
- 9.8.4 VSIS-1022 Event rule DTMF accepts invalid values
- 9.8.5 VSIS-1084 Cancel button in Wizard Review page
- 9.8.6 VSIS-1156 Scroll list on event received on Identify wizard does not have an effect
- 9.8.7 VSIS-1157 No warning message that port 69 is already in use
- 9.8.8 VSIS-1169 Password fields are not hidden
- 9.9 Known Issues ver. 1.4.3.5
- 9.1 New Features
- 10 Version 1.3.3.3
- 11 Version 1.3.3.2
- 11.1 Bugfixes and Improvements
- 11.1.1 MTN-920 Turbine stations can stuck in upgrade loop
- 11.1.2 VSIS-120 Ability to scan larger IP-ranges in VS-IMT
- 11.1.3 VSIS-128 Better presentation of upgrade file download file progress
- 11.1.4 VSIS-220 Upgrade never ends when stations are offline
- 11.1.5 VSIS-225 Better handle upgrade failures in case UDP port 69 is in use
- 11.1.6 VSIS-235 Upgrade button disabled when performing multiple upgrades
- 11.1.7 VSIS-238 IMT upgrade - missing notifications if another TFTP server is running
- 11.1.8 VSIS-239 Main window Upgrade is missing boot/environment upgrade option
- 11.1.9 VSIS-240 Remember last used firmware image
- 11.1.10 VSIS-249 Remove obsoleted Backup option
- 11.1.11 UNI-1474 Station gets TFTP_CONN_ERR because IMT sets wrong TFTP server IP (multiple interface exist, or returns 127.0.0.1)
- 11.1.12 UNI-1589 Upgrade timeout possible on more than 32 stations
- 11.1.13 SKI-277 Remove obsoleted audio profiles
- 11.1 Bugfixes and Improvements
- 12 Version 1.3.3.1
- 12.1 Bugfixes and Improvements
- 12.1.1 UNI-1322 IMT upgrade not handling blocked TFTP transfer - requires killing process
- 12.1.2 UNI-1433 IMT Standard Project - Main station list doesn't automatically update changed settings (dir.no, display name)
- 12.1.3 UNI-1434 IMT Wizard sets authentication user name to the wrong value
- 12.1.4 UNI-1459 "Call until answer" setting does not make Ringlist loop on Turbine
- 12.1.5 UNI-1462 Resolver assigns duplicate IP addresses to resolved INCA stations
- 12.1.6 UNI-1467 License upload through IMT says "could not be decoded" in case license key contains "+" character
- 12.1.7 UNI-1474 Station gets TFTP_CONN_ERR because IMT sets wrong TFTP server IP (multiple interface exist)
- 12.1.8 UNI-1480 "Enable full audio output" and "Volume override level" are not visible in IMT audio settings
- 12.1.9 UNI-1499 IMT Crashes on Inca upgrade (right after INCA downgrade)
- 12.1.10 UNI-1501 Changing Settings -> Zenitel MAC address requires restart of VS-IMT
- 12.1.11 UNI-1502 IMT report Failed upgrade when upgrade is successful
- 12.1.12 UNI-1523 VS-IMT Change IP address of an INCA station in VLAN environment mess up VLAN configuration
- 12.1.13 UNI-1525 Station search doesn't work
- 12.1.14 UNI-1526 IMT not able to upload license from ZAP project using Project Settings menu
- 12.1.15 UNI-1533 Issues with Trunk configuration when editing/deleting
- 12.1.16 SKI-96 DAK keys setup in IMT "VS-SDK for Pulse enabled" project not working
- 12.1.17 SKI-226 Not possible to configure DAK off in ZAP Event rules
- 12.1 Bugfixes and Improvements
- 13 Version 1.3.3.0
Release info
Name: Zenitel IMT
Description: Zenitel IMT is a software tool for managing Zenitel IP-intercoms. The software is delivered as Windows Installer package.
Version: 3.1.3.2
Date: 17.11.2022
Status: General Availability (GA)
Download: Link to download
Version 3.2.3.0
Fixed Issues
MTN-3911 Zenitel IMT 3.1.3.0 does not show all station settings when installed on top of VS-IMT 1.x/2.x version
Installing Zenitel IMT 3.1.3.0 version on top of IMT branded as Vingtor-Stentofon (VS-IMT) causes incorrect upgrade of IMT project database making station settings list limited. New Zenitel IMT version (>3.1.3.1) needs to be installed on top of 3.1.3.0 to fix the issue.
MTN-3891 Zenitel IMT does not allow downgrade of Stentofon EX-Panel-2 stations below version 6.1.3.0
Stentofon EX-Panel-2 stations (TFIX-1-V2, TFIX-2-V2, TFIX-3-V2, EAPFX-1-V2 and EAPFX-6-V2) are supported from version 6.1.3.0 and downgrading below that version bricks the device. In Zenitel IMT it is not allowed to perform such downgrade anymore.
Known Issues
MTN-2365 Upgrading INCA stations might fail in some very rare cases
In case station is not upgraded, simply run upgrade on failed stations again. In more severe cases, restarting station to factory defaults is necessary to make upgrade possible.
MTN-2364 IMT upgrade fails with multiple interfaces in same subnet
Issue caused by having both the WIFI and LAN interfaces on same subnet. Workaround: (1) By disabling the WIFI interface, the upgrade performed as intended; or (2) Change adapter priority in Network and Sharing Center -> Change adapter settings -> (Alt) Menu bar Advanced: Advanced Settings -> Adapters and Bindings
MTN-1730 VS-IMT uploading certificate to multiple stations at once will override all existing
Workaround: export properly configured set of certificates from a specific station with Export function under Certificates, select multiple stations and use Import to add all exported files, Save and Upload.
Version 3.1.3.2
Fixed Issues
MTN-3911 Zenitel IMT 3.1.3.0 does not show all station settings when installed on top of VS-IMT 1.x/2.x version
Installing Zenitel IMT 3.1.3.0 version on top of IMT branded as Vingtor-Stentofon (VS-IMT) causes incorrect upgrade of IMT project database making station settings list limited. New Zenitel IMT version (>3.1.3.1) needs to be installed on top of 3.1.3.0 to fix the issue.
MTN-3891 Zenitel IMT does not allow downgrade of Stentofon EX-Panel-2 stations below version 6.1.3.0
Stentofon EX-Panel-2 stations (TFIX-1-V2, TFIX-2-V2, TFIX-3-V2, EAPFX-1-V2 and EAPFX-6-V2) are supported from version 6.1.3.0 and downgrading below that version bricks the device. In Zenitel IMT it is not allowed to perform such downgrade anymore.
Known Issues
MTN-2365 Upgrading INCA stations might fail in some very rare cases
In case station is not upgraded, simply run upgrade on failed stations again. In more severe cases, restarting station to factory defaults is necessary to make upgrade possible.
MTN-2364 IMT upgrade fails with multiple interfaces in same subnet
Issue caused by having both the WIFI and LAN interfaces on same subnet. Workaround: (1) By disabling the WIFI interface, the upgrade performed as intended; or (2) Change adapter priority in Network and Sharing Center -> Change adapter settings -> (Alt) Menu bar Advanced: Advanced Settings -> Adapters and Bindings
MTN-1730 VS-IMT uploading certificate to multiple stations at once will override all existing
Workaround: export properly configured set of certificates from a specific station with Export function under Certificates, select multiple stations and use Import to add all exported files, Save and Upload.
Version 3.1.3.0
New Features
OV-27 VS-IMT has been rebranded to Zenitel IMT
MTN-3677 It is now possible to delete data.lua on several devices in one operation
DS-202 It is now possible to factory reset the audio parameters on several devices in one operation
Fixed Issues
MTN-3477 Fix to avoid false upgrade failures statuses (and to speed up the upgrade process)
Sometimes when upgrading devices using the IMT tool, devices got stuck at 99% during upgrade process.
Known Issues
MTN-2365 Upgrading INCA stations might fail in some very rare cases
In case station is not upgraded, simply run upgrade on failed stations again. In more severe cases, restarting station to factory defaults is necessary to make upgrade possible.
MTN-2364 IMT upgrade fails with multiple interfaces in same subnet
Issue caused by having both the WIFI and LAN interfaces on same subnet. Workaround: (1) By disabling the WIFI interface, the upgrade performed as intended; or (2) Change adapter priority in Network and Sharing Center -> Change adapter settings -> (Alt) Menu bar Advanced: Advanced Settings -> Adapters and Bindings
MTN-1730 VS-IMT uploading certificate to multiple stations at once will override all existing
Workaround: export properly configured set of certificates from a specific station with Export function under Certificates, select multiple stations and use Import to add all exported files, Save and Upload.
Version 2.2
Improvements
MTN-3363 Support for new products released in Q4 2021.
All new products released in Q4 2021 have sw upgrade support from this version of VS-IMT.
Known Issues
MTN-2365 Upgrading INCA stations might fail in some very rare cases
In case station is not upgraded, simply run upgrade on failed stations again. In more severe cases, restarting station to factory defaults is necessary to make upgrade possible.
MTN-2364 IMT upgrade fails with multiple interfaces in same subnet
Issue caused by having both the WIFI and LAN interfaces on same subnet. Workaround: (1) By disabling the WIFI interface, the upgrade performed as intended; or (2) Change adapter priority in Network and Sharing Center -> Change adapter settings -> (Alt) Menu bar Advanced: Advanced Settings -> Adapters and Bindings
MTN-1730 VS-IMT uploading certificate to multiple stations at once will override all existing
Workaround: export properly configured set of certificates from a specific station with Export function under Certificates, select multiple stations and use Import to add all exported files, Save and Upload.
Version 2.1
Improvements
TYR-90 Support for Tone test configuration
Added support for improved tone test configuration.
TYR-44 Compatible with VS-IS 6.1
MTN-3239 Support for video configuration
Added video settings configuration for TCIV+ and TKIV+ devices.
MTN-3219 Support for VLAN configuration
Added support for VLAN configuration for IP Master V2 stations.
MTN-2900 Projects in alphabetically order
Projects are now sorted alphabetically instead of last opened order.
Issues fixed
MTN-3295 Full version import and upgrade using VS-IMT fixed
Fixed issue with importing full VS-IS package and using the image for upgrade different devices at the same time
MTN-3283 Support for ICX AlphaCom
Fixed bug where VS-IMT does not show devices with updated AlphaCom name - "ICX AlphaCom" instead of "AlphaCom".
MTN-3110 Does not show warning for TCIV+ as Edge Controller
Warning for TCIV+ as Edge Controller is no longer shown.
MTN-3106 Proper handling for leading zeroes in directory number
Issue with handling of leading zeroes in directory number is now fixed.
MTN-3056 VS-IMT available for Windows usernames with special characters
Fixed bug where VS-IMT was not able to start when Windows username contained special characters. Now username can contain any UTF-8 character.
Known Issues
MTN-2365 Upgrading INCA stations might fail in some very rare cases
In case station is not upgraded, simply run upgrade on failed stations again. In more severe cases, restarting station to factory defaults is necessary to make upgrade possible.
MTN-2364 IMT upgrade fails with multiple interfaces in same subnet
Issue caused by having both the WIFI and LAN interfaces on same subnet. Workaround: (1) By disabling the WIFI interface, the upgrade performed as intended; or (2) Change adapter priority in Network and Sharing Center -> Change adapter settings -> (Alt) Menu bar Advanced: Advanced Settings -> Adapters and Bindings
MTN-1730 VS-IMT uploading certificate to multiple stations at once will override all existing
Workaround: export properly configured set of certificates from a specific station with Export function under Certificates, select multiple stations and use Import to add all exported files, Save and Upload.
Version 2.0
New Features
SUN-608 New Discover & Upgrade option added
A new option has been introduced in the VS_IMT tool; Discover & Upgrade. This option offers a simple discover and upgrade option which supports Vingtor-Stentofon devices.
From the new start page you can select Discover & Upgrade or Configuration Manager.
SUN-322 VS-IMT supports TCIV+, IP DMaster V2 and FCDC3
TCIV+ and IP Master V2 can be configured using the Configuration Manager option.
Upgrade of TCIV+, IP Master V2 and FCDC3 devices are only supported through the Discover & Upgrade option.
MTN-2756 HTTPS support in VS-IMT
Added function in VS-IMT to discover, identify, upgrade and configure Zenitel devices that have only HTTPS port opened. So, devices where HTTP port is disabled in the list of firewall rules. Using VS-IMT customer can now switch between HTTP and HTTPS using existing configuration mechanism.
Bugfixes and improvements
MTN-2949 VS-IMT reports error on saving settings for multiple AlphaCom devices
When multiple AlphaCom devices are selected in VS-IMT configuration window and settings are changed, you cannot save the changes due to reporting error message "Video mode SIP Call H.264 is not supported". Also valid for non-video devices. With this update this bug is fixed.
Known Issues
MTN-2365 Upgrading INCA stations might fail in some very rare cases
In case station is not upgraded, simply run upgrade on failed stations again. In more severe cases, restarting station to factory defaults is necessary to make upgrade possible.
MTN-2364 IMT upgrade fails with multiple interfaces in same subnet
Issue caused by having both the WiFi and LAN interfaces on same subnet. Workaround: (1) By disabling the WiFi interface, the upgrade performed as intended; or (2) Change adapter priority in Network and Sharing Center -> Change adapter settings -> (Alt) Menu bar Advanced: Advanced Settings -> Adapters and Bindings
MTN-1730 VS-IMT uploading certificate to multiple stations at once will override all existing
Workaround: export properly configured set of certificates from a specific station with Export function under Certificates, select multiple stations and use Import to add all exported files, Save and Upload.
Version 1.5
New Features
PHIX-75 VS-IMT limitations in Edge mode
VS-IMT supports discovery and upgrade of Edge devices (VS-IS 5.0). It doesn't support configuration of Edge devices. All configuration shall be done from web. VS-IMT still supports configuration of devices in SIP mode.
Known Issues
MTN-2365 Upgrading INCA stations might fail in some very rare cases
In case station is not upgraded, simply run upgrade on failed stations again. In more severe cases, restarting station to factory defaults is necessary to make upgrade possible.
MTN-2364 IMT upgrade fails with multiple interfaces in same subnet
Issue caused by having both the WIFI and LAN interfaces on same subnet. Workaround: (1) By disabling the WIFI interface, the upgrade performed as intended; or (2) Change adapter priority in Network and Sharing Center -> Change adapter settings -> (Alt) Menu bar Advanced: Advanced Settings -> Adapters and Bindings
MTN-1730 VS-IMT uploading certificate to multiple stations at once will override all existing
Workaround: export properly configured set of certificates from a specific station with Export function under Certificates, select multiple stations and use Import to add all exported files, Save and Upload
Version 1.4
New Features
VSIS-434 Turbine address book CSV download and upload
It is now possible to both upload and download a CSV file that contains Turbine address book entries. This is possible from both StationWeb and VS-IMT
VSIS-680 New Profile Management
VS-IMT Profile management is completely redesigned. Now it is very easy to create stations settings profiles from a single or multiple settings.
VSIS-681 Configuration tools redesign
It is now possible to configure multiple stations at once with common set of settings from both Wizard and Main window (with multi-select). File upload and download is also supported (audio messaging files, address book, SNMP configuration, etc.)
VSIS-746 Support for VS-IS 4.7 firmware settings
VS-IMT brings support for latest configuration options added to Turbine and INCA firmware in VS-IS 4.7 release.
VSIS-1079 Support for Exigo/PA firmware
VS-IMT can now be used to also do upgrades with Exigo firmware images
VSIS-1148 Project export includes all station files
Exported IMT project beside database file includes all files from stations in project. Everything is compressed in single archive file.
VSIS-1174 Mass configuration of 802.1x settings from VS-IMT
Added functionality in the VS-IMT to handle 802.1x network security settings for multiple stations at once. Both settings and security certificates (PKI) can be handled for many stations at once.
VSIS-1175 Mass configuration of INCA VLAN settings from VS-IMT
Added functionality in the VS-IMT to handle VLAN network settings for multiple INCA stations at once.
VSIS-1180 Upgrade crash rescue mode
Added functionality to detect IP stations that did not successfully finish firmware upgrade process. A special Station Rescue tool is implemented for such stations to finish the firmware upgrade.
Bugfixes and improvements ver. 1.4.3.5
SNOW-1111 ENA-2060/2100 support in VS-IMT
ENA-2060 and ENA-2100 are supported from 4.10
SNOW-1033 Show warning for non-supported target firmware upgrade version
VS-IMT now shows "Not supported" warning/error when a station is selected for upgrade with not supported firmware set for upgrade
SNOW-1001 Support for syslog configuration
IMT now supports syslog settings
SNOW-983 Support for new DAK call actions
Added support for Defer and Park Call function
SNOW-422 VS-IMT upgrade: Automatic selection of imported image
When firmware image is imported to VS-IMT it is automatically selected, so users have no additional step to perform upgrade with new image except click on Upgrade button.
SNOW-1264 Support for VS-IS 4.11 firmware settings
VS-IMT brings support for latest configuration options added to Turbine and INCA firmware in VS-IS 4.11 release.
Bugfixes and improvements ver. 1.4.3.4
SNOW-918 TCIV-5 support in VS-IMT
New TCIV-5 is now supported in VS-IMT
MTN-1872 Export VS-IMT logs from all IP stations
Using new option under VS-IMT Settings, it is now possible to collect and export all VS-IMT logs (for all IP stations) from current session into the archive file. This comes very handy where troubleshooting needs to be done for VS-IMT.
SNOW-581 IMT Changes: New devices added
ENA2060-DC and ENA2100 can now be updated from IMT
SNOW-422 VS-IMT upgrade: Automatic selection of imported image
When firmware image is imported to VS-IMT it is automatically selected, so users have no additional step to perform upgrade with new image except click on Upgrade button.
SNOW-582 IP-LCM support in VS-IMT
IP-LCM is now supported in VS-IMT
SNOW-473 TKIS-3 and TKIE-4 support in VS-IMT
TKIE-3 and TKIE-4 can now be upgraded from IMT
Bugfixes and improvements ver. 1.4.3.3 (GA)
VSIS-1231 VAD Minimum amplitude (dBA) can't be set for INCA stations in VS-IMT
Added configuration option for INCA stations.
VSIS-1147 VS-IMT Wizard sets static IP address without Gateway
This makes issues in Pulse system like Group Call not working correctly. It also causes stations non-accessible from other LAN segments. Fixed with adding Static IP address + netmask, and gateway IP address settings to Wizard.
SNOW-385 VS-IMT - Warning label for TCIV as Pulse server
Added limitation warning for TCIV when configured as Pulse server
SNOW-239 Enable all DAK actions for all Turbine stations in VS-IMT
All DAK actions are now enabled for all Turbine stations, not filtered anymore by station type.
MTN-1748 VS-IMT firmware image import should have progress bar
Copying and unzipping image can take some time - especially when done over the network, so it is good to have progress bar on that action. Fixed by adding GUI progress bar.
MTN-1421 Noise Reduction level should not be configurable from IMT in AlphaCom mode
Removed the configuration option.
MTN-1012 VS-IMT not showing licenses if INCA is Pulse server
Fixed.
Bugfixes and improvements ver. 1.4.3.2 (GA)
MTN-1686 No notification for long-running project Imports
Project import for large projects (100+ stations) can take some time (up to 10 seconds). Improved GUI by adding progress bar to both Import and Export project
MTN-1436 Performance issues on projects with a lot of IP stations
Saving configuration or opening projects that consist of lot of IP stations could take a lot of time. Fixed with performance optimizations on the VS-IMT database layer.
MTN-976 VS-IMT - crash on Win 8.1 virtual machine
When trying to add new stations to existing project, IMT will sometimes crash on Win 8.1 in Virtual Machine. Station will be added to the project and will be visible when IMT is restarted. This cannot be reproduced on Win 7 or 10, both physical or VM.
Bugfixes and improvements ver. 1.4.3.1 (GA)
MTN-1675 Image upgrade user notifications
User notifications during image upgrade have been changed to provide better feedback to end users.
MTN-1674 Better handling of boot environment image upgrade process
If a specific firmware image requires boot environment upgrade, the upgrade will now be performed automatically. The user will no longer have to select that option. It is now also possible to select additional options related to boot environment upgrade.
Bugfixes and improvements ver. 1.4.3.0 (GA)
VSIS-1229 INCA with 02.02.3.1 in reboot loop after configuration
Fixed with adding minimal firmware version check: if less than 02.03.3.3 for INCA, 02.03.3.1 for Dual Display INCA, and 3.0.3.4 for Turbine, firmware upgrade is made mandatory before station can be configured and added into VS-IMT project
Bugfixes and improvements ver. 1.4.2.4 (LA)
VSIS-593 Switching Turbine station between DHCP and Static IP fails in some cases
In cases when changing between static and DHCP IP address is done multiple times, it is possible that setting static IP address will fail.
VSIS-833 Wizard should ask to apply changes to Pulse server directory
Possibility to choose if Pulse server directory should be affected by changes made on configure step of wizard. When this option is not set, only SIP settings (client) will be applied to stations.
VSIS-881 VS-IMT sets headset on Turbine Compact
Turbine Compact does not have accessory setting available and this setting is now exposed to Turbine Extended stations only.
VSIS-1022 Event rule DTMF accepts invalid values
In VS-SDK project event rules setup allows only valid values.
VSIS-1084 Cancel button in Wizard Review page
Added opportunity to cancel adding stations to the project on last (review) step of wizard.
VSIS-1156 Scroll list on event received on Identify wizard does not have an effect
Fixed scroll list function.
VSIS-1157 No warning message that port 69 is already in use
Warning message is presented in case any application that is using port 69 is running in the moment VS-IMT upgrade start. Previously there was an issue with presenting such message on Windows 10.
All text input fields that are not shown as plain text fields on station web (e.g. passwords) are now not visible as plain text in IMT either.
Known Issues ver. 1.4.3.5
MTN-2365 Upgrading INCA stations might fail in some very rare cases
In case station is not upgraded, simply run upgrade on failed stations again. In more severe cases, restarting station to factory defaults is necessary to make upgrade possible.
MTN-2364 IMT upgrade fails with multiple interfaces in same subnet
Issue caused by having both the WIFI and LAN interfaces on same subnet. Workaround: (1) By disabling the WIFI interface, the upgrade performed as intended; or (2) Change adapter priority in Network and Sharing Center -> Change adapter settings -> (Alt) Menu bar Advanced: Advanced Settings -> Adapters and Bindings
MTN-1730 VS-IMT uploading certificate to multiple stations at once will override all existing
Workaround: export properly configured set of certificates from a specific station with Export function under Certificates, select multiple stations and use Import to add all exported files, Save and Upload.
Version 1.3.3.3
Bugfixes and Improvements
MTN-1070 Station upgrade on more than 16 stations got stuck in case when network is down
When network is down and first 16 stations timeout, others were stuck in queue. Now, stations after 17th will also start to exit from queue and start with upgrade.
MTN-1078 Network interruptions during station upgrade can leave station in boot loop
When network is temporary suspend on some (or all) stations during upgrade it forces station to re-initiate TFTP transfer. New file transfer was marked as already in use by IMT and rejected. In some cases that left station in boot loop. Now, all transfer requests from stations are accepted and handled.
Version 1.3.3.2
Bugfixes and Improvements
MTN-920 Turbine stations can stuck in upgrade loop
Interrupted upgrade process can leave station broken. IMT now have possibility to detect such situations and offers station recovery - it opens TFTP server and listens for station requests.
VSIS-120 Ability to scan larger IP-ranges in VS-IMT
IP discovery can now be started on range of any size
VSIS-128 Better presentation of upgrade file download file progress
Upgrade file download process is presented with name of each file to avoid misconception that upgrade process is repeating image download.
VSIS-220 Upgrade never ends when stations are offline
Upgrade button is now only enabled when stations are selected and upgrade is not in progress.
VSIS-225 Better handle upgrade failures in case UDP port 69 is in use
Introduced pop-up saying that TFTP cannot bind to port 69 and pointing user to check and close other application that are using port 69.
VSIS-235 Upgrade button disabled when performing multiple upgrades
Upgrade button enabled/disabled policy updated.
VSIS-238 IMT upgrade - missing notifications if another TFTP server is running
In case IMT upgrade is started while another TFTP server is running, IMT upgrade will fail, but it will be presented as upgrade is completed. Only by looking in log file and error log, reason for failure can be observed.
VSIS-239 Main window Upgrade is missing boot/environment upgrade option
Missing checkbox for enabling boot/environment upgrades in main window Upgrade
VSIS-240 Remember last used firmware image
Last image used for upgrade is remembered and auto selected on next upgrade.
VSIS-249 Remove obsoleted Backup option
Obsolete "Backup" option from Tools menu is removed. Project "Export/Import" should be used instead.
UNI-1474 Station gets TFTP_CONN_ERR because IMT sets wrong TFTP server IP (multiple interface exist, or returns 127.0.0.1)
Upgrade fails with TFTP_CONN_ERR when multiple interfaces exists (common when upgrading through VPN) as IMT set wrong TFTP server IP. Fixed by choosing interface based on upgrade station IP address and offering user to select IP address manually.
UNI-1589 Upgrade timeout possible on more than 32 stations
Fixed bug where stations reported "Aborted" status on upgrade of more than 32 stations at once.
SKI-277 Remove obsoleted audio profiles
Obsolete "standard_pc" and "embedded_pc" audio profiles removed from VS-IMT.
Version 1.3.3.1
Bugfixes and Improvements
UNI-1322 IMT upgrade not handling blocked TFTP transfer - requires killing process
Timeout implemented in IMT upgrade mechanism that takes of situation when e.g TFTP transfer is blocked or network is disconnected during upgrade and similar. Upgrade will be marked as "Failed" on those stations once timer exceeds.
UNI-1433 IMT Standard Project - Main station list doesn't automatically update changed settings (dir.no, display name)
If some station settings (dir.no, display name) were changed in station settings the change was not reflected in main station list. This fix is made in the manner that 'Display name', 'Dir. no' and 'Server IP' values are updated in the main list once they are successfully uploaded to station.
UNI-1434 IMT Wizard sets authentication user name to the wrong value
When uploading changes in Wizard, authentication user name was set to same value as authentication password. Resolved by adding option for users to edit authentication user name on their own during Standard Wizard Pulse system configuration.
UNI-1459 "Call until answer" setting does not make Ringlist loop on Turbine
In Ringlist settings when "Call until answer" is checked Turbine station doesn't loop through Ringlist as expected. String "Call until answer" is changed to "Loop Ringlist" Max loop number was set to 0 and there were no possibility to change this number. Now when "Loop Ringlist" is checked user get additional setting "Max Loop Number" when it can set how many times Ringlist will be iterated. Also setting "Max Loop Number" to 0 now mean that Ringlist will be looped until call is establish. Also updated the related settings in VS-IMT
UNI-1462 Resolver assigns duplicate IP addresses to resolved INCA stations
Factory resolver was stopped before all stations booted up. In case user run resolver again, it was very likely that resolver will assign "available" addresses to new stations even though those addresses are already assigned to stations that are not booted yet. Issue is fixed and now resolver stops only after all stations boot up.
UNI-1467 License upload through IMT says "could not be decoded" in case license key contains "+" character
Fixed by using HTML encoding for license key.
UNI-1474 Station gets TFTP_CONN_ERR because IMT sets wrong TFTP server IP (multiple interface exist)
Upgrade fails with TFTP_CONN_ERR when multiple interfaces exists (common when upgrading through VPN) as IMT set wrong TFTP server IP. Fixed by choosing interface based on upgrade station IP address.
UNI-1480 "Enable full audio output" and "Volume override level" are not visible in IMT audio settings
Added support in IMT for those two settings.
UNI-1499 IMT Crashes on Inca upgrade (right after INCA downgrade)
Fixed occasional IMT crash when upgrading stations that are not connected to network in the moment upgrade has been initiated.
UNI-1501 Changing Settings -> Zenitel MAC address requires restart of VS-IMT
Global settings (Zenitel MAC address prefix, factory IP address and factory resolver interface IP address) are applied immediately when updated in IMT Options. No need for VS-IMT restart any more.
UNI-1502 IMT report Failed upgrade when upgrade is successful
Fixed occasional cases when IMT reported Failed upgrade even if upgrade was successful.
UNI-1523 VS-IMT Change IP address of an INCA station in VLAN environment mess up VLAN configuration
Fixed issue that caused loss of VLAN list on station after execution of configure step in IMT wizard.
UNI-1525 Station search doesn't work
Fixed issue in IMT search that caused search not working when search text contained numbers.
License upload in VS-SDK for Pulse enabled project through Project Settings fixed.
UNI-1533 Issues with Trunk configuration when editing/deleting
Fixed trunk mess (e.g. duplicated and non-deletable trunks) after edit/delete action performed on existing trunks.
SKI-96 DAK keys setup in IMT "VS-SDK for Pulse enabled" project not working
Simplified UI for DAK keys setup in ZAP Event Rules and fixed issue that caused them not working.
SKI-226 Not possible to configure DAK off in ZAP Event rules
Fixed issue with setting up action when DAK key is OFF in VS-SDK project's ZAP Event Rules
Version 1.3.3.0
VS-IMT 1.3.3.0 is the first release.
Known issues
UNI-1567 IMT upgrade fails with multiple interfaces in same subnet
Issue caused by having both the WIFI and LAN interfaces on same subnet. Workaround: (1) By disabling the WIFI interface, the upgrade performed as intended; or (2) Change adapter priority in Network and Sharing Center -> Change adapter settings -> (Alt) Menu bar Advanced: Advanced Settings -> Adapters and Bindings
VSIS-149 Upgrading INCA stations might fail in some very rare cases
In case station is not upgraded, simply run upgrade on failed stations again. In more severe cases, restarting station to factory defaults is necessary to make upgrade possible.