DISPLAY TEXT
From Zenitel Wiki
DISPLAY_TEXT | 0x005A | 90 | AMC 06.00 | |
---|---|---|---|---|
1 | NET_OBJ_REF<br\>{ECL_STATION} | Station. Null value not allowed.<br\>. | ||
$DSPL L101 U18 0311 ‘Line 1 text’<br\>
$DSPL L101 U18 0312 ‘Line 2 text’<br\> $DSPL L104 U23 0313 14 "Line 3 text on CRM "<br\> $DSPL L104 U23 0313 54 "Line 4 text on CRM "<br\> Dual Display (from AMC 08.28 / 09.01):<br\> 1. $DSPL L104 U11 33011302 ‘DAK line’<br\> 2. $DSPL L104 U3 500400 ‘’<br\> | ||||
Send text and control characters to a station in a station dependent low level format.<br\>
The character set is ISO 8859 (for characters from 20 hex an above). The control characters used conforms to the TouchLine display format code for control of the display.<br\> AlphaNet: Message from remote exchange in order to display the enclosed text in a local station.<br\><br\> Note that the exchange updates the display frequently, and external control of the display will work only in special situations.<br\><br\> Dual Display:<br\> Example 1. Update text on DAK display line 02. legal values 01->64 (1-100 decimal)<br\> Example 2. Select (show) DAK page 04 on DualDisplay station with no arrow indication (last 00. Arrow down is visible if (last) number is 2 or more. Arrow up is visible if number is larger than the page number). | ||||
1 | NET_OBJ_REF<br\>{ECL_STATION} | Station displaying text.<br\>AlphaNet: B station in B exchange. | ||
2 | UINT1 | Length of text | ||
3 | Array of UINT1 | Text characters. |