ZDD - Restore Factory Defaults

From Zenitel Wiki

A ZDD-1 may have to be reset to its original factory default settings if, for instance, the password to the station web interface is forgotten. The device can be set to either obtain IP address from a DHCP server, or to a Static IP address.

Software reset

Factory default settings can be restored from the web interface.


Hardware reset

The ZDD-1 can be set to factory default by connecting a push button to input 1, and operating this button while the station is starting up.

Preparation

Connect a button between I/O 1 and GND. The cable range of the connector: AWG 16-28

ZDD-1 FactoryDefault.png
Connecting a push button to Input 1

Reset to Factory Default Settings - IP address obtained from DHCP

  1. While pressing the button, power up the station by connecting it to a PoE switch
  2. Hold the button until the station audio starts counting, and release the button on count 1
  3. Press and hold the button on count 5 and release on count 0
  • If there is no 0 count, the procedure has failed and you have to start again
  • Press the button, and the station will speak its IP address

Factory default values

Station IP address: Determined by DHCP server. If no DHCP server is available, it gets a random 169.254.x.x address.
Default username: admin
Default password: alphaadmin

Reset to Factory Default Settings with Static IP

  1. While pressing the button, power up the station by connecting to a PoE switch
  2. Hold the button until the station audio starts counting, and release the button on count 1
  3. Press and hold the button on count 3 and release on count 0
  • If there is no 0 count, the procedure has failed and you have to start again
  • Press the call button, and the station will speak its IP address

Factory default values

Station IP address: 169.254.1.100
Default username: admin
Default password: alphaadmin