PROGRAM 0x0001 1 AMC 05.00
$PROG L101 L801 U1

$PROG L101 LV

Set Audio Program for single station or a predefined group of stations.
1 NET_OBJ_REF{ECL_STATION, ECL_ST_GROUP} A - user or station.
2 NET_OBJ_REF{ECL_PROGRAM} Audio program

- Null value or directory number for “program off” disconnects any active program(s).

3 UINT1 Priority
  • 1 = Low
  • 2 = Medium (default)
  • 3 = High
  • 4 = Alarm
Response: PROGRAM_ACK, PROGRAM_NAK