Syntax

MPP  <"pager-address"/pager-id>  <source.phys.no>  <"mail-text"/mail-id> [<beepcode>] [<no-transm>] [<prior>]
  • Receiving pager:
    • <pager-id> is configured pager number 1 - 600.
    • Or the address of the pager receiver in "", in record type 1 of ESPA 4.4.4 message. Settings for pager number 1 is used. This option introduced in AMCD 10.52.
  • <source.phys.no> is Physical number considered as sender of paging, used for filling in predefined mails. Not used for Free text mails, use 0.
  • Text sent to pager (in record type 2 of ESPA 4.4.4 message)
    • Mail text: Free text (maximum 128 characters) in quotes. (Prior AMCD 10.52 max 16 characters.)
    • or a Predefined AlphaCom mails number
  • <beepcode> : 0-9 Beep code sent to paging system, in record type 3 of ESPA 4.4.4 message.
  • <no-transm> : 1, 2.. Number of transmissions, code sent to paging system, in record type 5 of ESPA 4.4.4 message.
  • <prior> : 1 , 2 or 3: Priority sent to paging system, in record type 6 of ESPA 4.4.4. 1 = Alarm; 2 = High; 3 = Normal


Examples

MPP 2 0 "Temp. alarm" – Send text-message to pager 2
MPP "1024" 0 "Temp. alarm" – Send text-message to pager with address "1024" 
MPP 1 3 10 - Send Call-me message (10) from station 3 to pager 1