AMG - Alarm Message to Group
From Zenitel Wiki
AMG is used to play prerecorded audio message to a group of stations. The feature is using Volume Override, and will play the message at full volume.
Syntax
AMG <group.no>
- <group.no> = The index number of the group (1-250)
= The index number of the audio message (1-80)
From software version 11.5.3.1:
AMG <group.no><hvo>
- <hvo> Optional parameter "handset volume override". 1 = on, 0 = off. Default = 1
Examples
AMG 4 3 – Alarm message 3 (8193) to group 4 (87) AMG 4 0 – Alarm message OFF to group 4 (87) AMG 4 3 0 – Alarm message 3 (8193) to group 4 (87), without volume override