Actions

Open Duplex Conferences (AlphaPro)

From Zenitel Wiki

Revision as of 14:52, 4 December 2012 by Tobias (talk)
Open Duplex Conference.png
Conference Number Reflects the conference highlighted in the listbox to the left
Description Her you enter the conference name, max 32 characters. The name is used in the listbox to the left. The information is not transferred to the exchange, but stored in the PC file
Master When this station leaves the conference the whole conference is cancelled
Setup Priority The priority setting specifies the priorities between the conferences

The following options are available: Low, Normal, High, Alarm Low, Normal and High:

  • No difference, the conferences are sorted by time of activation. On conference to group: If one participant is occupied, it is just left out of the group setup. No warning is given.

Alarm:

  • Cancels any other conference for the stations included in the conference
  • Cancels any ongoing conversation for the stations in the conference.

If a station is in an alarm conversation (call from a station with alarm priority) the conference will not cancel the conversation.

  • Seizes any necessary duplex mixing resources (AGA (and/or AMC-IP from AMC 10.50))