Actions

GROUP MSG

From Zenitel Wiki

Revision as of 12:59, 23 September 2010 by Aksel (talk)
GM (GROUP_MSG) 0x00A6 166 AMC 11.00
$GM L84 L8181
$GM L85 L8193 U1 U0 U0
$GM L9001 L8182 U10 U0 U0
$GM NG1 N!4 U3 U2 U0
No repetition and use group gong and priority <br\> No repetitions and no gong <br\> 10 repetitions and no gong
To group 1 (84), activate alarm message 4 (8194), 3 repetitions, use gong type 2 (dong-ding).
GROUP_MSG sets up a local or global group call with source a SVP message. To stop message playback use GROUP_MSG_STOP
1 NET_OBJ_REF <br\>{ECL_LOCAL_GROUP, <BR\> ECL_GLOBAL_GROUP} Destination local or global group
2 NET_OBJ_REF<br\>{ECL_ANNOUNCEMENT} Announcement message for playback in group.
3 UINT1<BR\>(optional) SVP Message repetitions 0-255. 0 or unspecified means 1 repetition. 255 means repeat indefinitely (use GROUP_MSG_STOP to stop).
4 UINT1<BR\>(optional) Gong type. 0 = no gong. 255 or unspecified = use gong type of group.
5 UINT1<br\>(optional) Group call priority, default 0 = use priority of group call.
1 = Low, 2 = Medium, 3 = High, 4 = Alarm
Response none



Back to AlphaNet message list