System configuration



Configuration

Configure the IP Substation

  • Perform a "Factory Default" setting on the IP Substation
    • Press the call button
    • While the button is pressed, connect the IP Substation to the PoE switch
    • Wait until the call LED of the station starts to flash
    • Release the call button for exactly two flashes
    • Push the button briefly
  • Assign the PC an IP address in the range 169.254.x.x
  • Connect the PC to the network switch
Accessing the IP Substations web page


  • On the PC start a web browser, and enter the IP station address 169.254.1.100 in the address field
  • Log in with Username: admin, password: alphaadmin
  • Select CCoIP Configuration, and enter the following parameters:
Enter the IP settings in the IP Station web page


  • Connect the IP substation and the AlphaCom XE (Eth1) to the same network switch

Configure the AlphaCom XE

  • In AlphaPro go to Users & Stations, and select physical number 39; 139 Station 39
  • Use the section on the right and change the configuration as follows:
AlphaPro: Users & Stations window


Call Button

  • In AlphaPro, Users & Stations, select physical port 39. Then press the button DAK, and configure as follows:
AlphaPro: Users & Stations -> DAK window



  • Send the changes to the AlphaCom XE

SendChg.PNG

Troubleshooting

  • If the IP station does not register, check the following:
    • In AlphaWeb, System Configuration -> Filters, verify that port for IP Stations and VoIP Audio is enabled